INNER RANGE IQ. PLUS Programmer’s Manual.
SYSTEM INPUTS
NOTES:
1)
If the Siren output is not used, or a High impedance device is connected (e.g. Piezo siren), a 6k8 resistor must be installed across the Siren output to prevent the Siren Monitor Alarm
from being activated.
2)
Period specified by Telecommunications authority requirements.
3)
Siren and Dialler operations for Keypad System Input alarms (Medical, Panic, Duress and Fire ) are programmed in the “Emergency Options” programming. (Address 899)
4)
“View Fault History” (<NEXT>, 13) uses the Zone Lamps to display any System Inputs that have had an alarm in the last 5 Arming periods. Flash=Currently in alarm. ON=History.
ALARM
INPUT
No.
Zone
Lamp *4
DESCRIPTION
Goes Into Alarm when:
Restores when:
AC Fail
101
1
The AC mains has been absent for more than the specified time period (AC Fail Delay).
When the input is in alarm the PWR indicator on theTerminal will flash.
Note: The "FAULT" Lamp will be come ON instantly when AC is absent.
The AC mains is restored.
Low Battery
102
2
The battery voltage falls below 10.5V during Battery Test or while AC supply is not present. (Indicates Battery
voltage is too low to provide backup power if AC fails.)
Next successful Battery Test.
Cabinet Tamper
103
3
The Control Panel cabinet cover is removed or the cabinet is removed from it's mounting surface, causing the
Tamper Input to go unsealed.
PIN <OFF> is entered when Cabinet Tamper Input is
Sealed.
Siren Monitor Alarm
104
4
The Siren speaker is disconnected from the Control Panel.
*1
The Siren speaker connection is restored.
PWR Fuse fail
105
5
Power fuse has blown. (Due to Short circuit or over-current condition.)
The fuse has been replaced.
Battery Fuse fail
106
6
Battery fuse has blown. (Due to Short circuit or over-current condition.)
The fuse has been replaced.
Comms Fail
107
7
System failed to report.
The system in unsuccessful in calling the receiving party after the "Maximum Attempts" on both the primary and
secondary telephone numbers. (The system will try to dial again after waiting 30 minutes.)
*2
On the next successful call.
System Reset / RTC
Problem
108
8
The Control panel microprocessor has been reset. e.g. AC and Battery power lost and restored.
(The Time and Date will be incorrect and should be reset with the <NEXT>, 33 function)
PIN <OFF> is entered
Keypad Lockout
109
9
The System has registered 5 incorrect PIN code attempts in a row.
The system will not allow keypad access for a specified period of time. (See KEYPAD LOCKOUT TIME.)
The lockout period has expired.
Zone Self Test Fail
110
10
Any zone flagged as a self-test zone has failed the self-test criteria.
No restoral generated.
Keypad Medical Alarm
*3
111
11
Medical Alarm has been activated on a Terminal keypad.
No restoral generated.
Keypad Panic Alarm
*3
112
12
Panic Alarm has been activated on a Terminal keypad.
No restoral generated.
Keypad Duress Alarm
*3
113
13
A Duress PIN code has been entered on a Terminal keypad.
No restoral generated.
Keypad Fire Alarm
*3
114
14
Fire Alarm has been activated on a Terminal keypad.
No restoral generated.
Door Forced Alarm
15
Activated when the reed switch goes into alarm withouta valid request to open the door
PIN <OFF> is entered; or card swiped
Door Held Open too Long
16
Activated when the door is open for longer than a period equal to 4 times that of the time set at location 909
Door Closed
Test Report
120
Automatic (Periodic) or Manual Test Report is triggered.
No restoral generated.