p52
Ver. 3.604 (31/03/05)
INNER RANGE IQ. PLUS Programmer’s Manual.
TEST REPORTING (PERIODIC TEST REPORT TO CENTRAL STATION)
The following Addresses set the frequency of automatic Test reports and the time of day the Test Report is to be sent to the Central
Monitoring Station. Test Reporting verifies that the alarm reporting function of the system is operational, and is particularly useful for
providing a regular test transmission to the Central Monitoring Station when Open/Close reporting is not used.
e.g.
If the “Test Report period” option is set to 7, the “Test Report Hour” is set to 22, and the “Test Report Minute” is set to 45;
Then a Test Report will be sent to the Central Monitoring Station at 10:45 PM every seven days.
TEST REPORT PERIOD
(0 TO 255 DAYS)
This option sets the number of days between the automatic Test Reports.
(i.e. How often a Test Report will be sent)
0 to 255 Days.
0 = No Test Reporting.
TEST REPORT HOUR
(0 - 23 HOUR)
This Address sets the hour that the test report will be sent.
TEST REPORT MINUTE
(0 - 59)
This Address sets the minute the test report will be sent.
REMOTE CONNECT OPTIONS
These options allow the Installer to program parameters relating to remote connection for Upload/Download and/or DTMF Telephone
remote control. Remote connect for Upload/Download is restricted to the Installer and User Types 6 (Arm/Dis-arm/Isolate) and 7 (Master).
Notes: 1)
The Baud rate for Upload/Download when remotely connected is fixed at 300 Baud.
2)
There is a 2 minute delay between dial-in attempts to enhance protection against unauthorized access into the system.
i.e. Once you have disconnected from the panel, please wait at least two minutes before attempting to connect back in
REMOTE CONNECT METHOD
This Address sets the remote connect method for programming the system with the Upload / Download software.
Review records the login event and the User number logging in.
509
510
511
512
(Value Data)
7 Days
3
30
(Value Data)
1 - Enabled
ADDRESS
DEFAULT
FUNCTION
(Data Type)