Ver. 3.604 (31/03/05)
p85
INNER RANGE IQ. PLUS Programmer’s Manual.
FACTORY DEFAULT AND INSTALLER PRESET CONFIGURATIONS
ADDRESS
DESCRIPTION
FACTORY DEFAULT
INSTALLER PRESET 1
NO DIALER
INSTALLER PRESET 2
CONTACT ID DIALER
INSTALLER PRESET 3
DOMESTIC DIALER
505
Reporting Format
0
0
1
2
506
Dialler Options
1,2,3
0
2,3,4,7
1
507
General Open / Close Area List
1
1
1
1
508
Maximum Dial Attemps
8
8
8
8
509
Test Report Period
7
0
7
7
510
Test Report Hour
3
3
3
3
511
Test Report Minute
30
30
30
30
512
Remote Connect Method
1
1
1
1
513
Rings to Answer
9
9
9
9
514
Answer Machine (Fax) Bypass
0
0
0
0
515
Port 0 comms task
1
1
1
1
516
Port 0 Baud Rate
3
3
3
3
517
Port 1 comms task
2
2
2
2
518
Port 1 Baud Rate
3
3
3
3
521
Area1 Client Code
9999
9999
9999
9999
522
Area2 Client Code
-
-
-
-
523
Area3 Client Code
-
-
-
-
524
Area4 Client Code
-
-
-
-
531
General Area / Area 1 Entry Delay Time
30
30
30
30
532
Area 2 Entry Delay Time
30
30
30
30
533
Area 3 Entry Delay Time
30
30
30
30
534
Area 4 Entry Delay Time
30
30
30
30
541
General Area / Area 1 Exit Delay Time
60
60
60
60
542
Area 2 Exit Delay Time
60
60
60
60
543
Area 3 Exit Delay Time
60
60
60
60
544
Area 2 Exit Delay Time
60
60
60
60
There are four pre-defined settings available to the Installer:
The
Factory Default,
and Three “8 Zone / Single Area”
Installer presets: 1-No Dialer 2-Contact ID Dialer 3-Domestic Dialer.
CAUTION: Defaulting the system overwrites all configuration values currently programmed in memory.
The following table provides details of the programming performed by the 4 Default Options. Hardware reset , sets the Factory Defaults,
in cases where the password is lost or the Terminal is not functioning. The other presets are set using, NEXT 098.
The factory default settings are also shown throughout the programming reference section of this manual. Details of the defaulting procedure are provided on page 16.
(Hardware Reset; Short pins 2&3 of the flash
header for at least 5 seconds while powering up),
FLASH
J-TAG
1
2
3