INNER RANGE IQ. PLUS Programmer’s Manual.
USER AUXILIARIES
1) Assign the Auxiliary Event Type to the selected Auxiliary to control.
NEXT 801 (Aux 1), to 810 (Aux 10)
Type 13 - “User Auxiliary A”
Type 14 - “User Auxiliary B”
2) Program an Auxiliary Timer value for the selected Auxiliary.
NEXT 831 (Aux 1), to 840 (Aux 10)
3) Assign the required “Auxiliary Action” for the selected Auxiliary.
NEXT 861 (Aux 1), to 870 (Aux 10)
2 - One-shot timed in Seconds.
3 - One-shot timed in Minutes.
Types 4 to 13 may also be suitable.
See Section 10 -”Tables” page 82 for details of all Auxiliary Actions.
4) Program one or more User PIN Codes for “User Auxiliary” operation.
NEXT 403 to 447
Set the User Type to Type 4 - “User Auxiliary A”
Type 5 - “User Auxiliary B”.
NOTE: User Auxiliary PIN Codes cannot be used to perform any other operations.
WALK TESTING
1) Program the “Walk Test Time” (0 to 255 Minutes. Factory Default = 30 Minutes)
NEXT 912
(Maximum period that the system can remain in Walk Test Mode)
2) Program/Check the Users who require access to Walk Test Mode.
NEXT 403 to 447
Program a PIN Code, Assign the Area/s required, and set the User Type to Type 7 - “Master”.