Ver. 3.604 (31/03/05)
p23
INNER RANGE IQ. PLUS Programmer’s Manual.
6.
ENABLE/DISABLE THE SYSTEM INPUT ALARMS THAT ARE REQUIRED TO ACTIVATE THE SIREN.
NEXT 897.
4.
PROGRAM ANY ADDITIONAL BASIC OPTIONS FOR ZONE INPUTS.
NEXT 651 to 666
5.
PROGRAM THE SIREN SWINGER SHUTDOWN COUNT.
NEXT 913
DEFAULT: 16
(Only required if the “Siren Lockout” option is selected for any Zones in the Zone Options above)
Program the number of times (0 to 255) the Siren can be triggered by a Zone Input in a single Arming period before Siren Lockout occurs.
(The counter is reset when the Area is turned Off)
7.
ENABLE/DISABLE THE KEYPAD EMERGENCY ALARMS THAT ARE REQUIRED TO ACTIVATE THE SIREN.
NEXT 899.
1
Silent
When selected, Siren is not activated when an alarm is triggered on this Zone. (NOTE: “Silent” over-rides “Siren Lockout”)
2
Siren Lockout
Zone will only trigger the Siren for the number of times specified in the “Siren Swinger Shutdown Count”. (Address 013)
7
Change Sense
(Normally Open Contacts)
The “Sealed” and “Alarm” states are swapped so that an alarm is triggered when an Open to Closed transition occurs on the detector contacts.
May be required for smoke detectors, etc.
t
t
t
t
1
Panic Alarms will activate the Siren.
Enabled by default
3
Fire Alarms will activate the Siren.
Enabled by default
5
Medical Alarms will activate the Siren.
Enabled by default
1
AC Fail.
3
Cabinet Tamper. (Enabled by default)
5
Comms Fail / System Reset / Real-time Clock Problem.
7
LAN Fuse / Battery Fuse.
2
Low Battery
4
Keypad Lockout.
6
Siren Monitor
Zone
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Address
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666