Ver. 3.604 (31/03/05)
p29
INNER RANGE IQ. PLUS Programmer’s Manual.
Contact ID or Domestic Dialer Reporting.
No Reporting.
Go to Step 30.
“User Programming”
t
t
18.
PROGRAM THE PRIMARY AND SECONDARY TELEPHONE NUMBERS.
Primary Telephone Number.
NEXT 500
Program the Primary Telephone number for Reporting.
Up to 16 digits allowed.
Secondary Telephone Number.
NEXT 501
If required, program a Secondary Telephone number for Reporting.
Up to 16 digits allowed.
Programming Telephone number digits:
0 to 9 = 0 to 9
10 = *
11 = #
12 = 4 Second pause
Multi-digit numbers are entered by pressing the <OFF> key.
e.g. To program a #, Press <OFF>, 1, 1.
19.
SELECT THE REPORTING FORMAT.
NEXT 505
Note: If Dual Reporting is required, select Option 8 FIRST. Refer to Programming Advanced Features Section 8 and
Programming Reference, Section 9 for further details.
Is the Reporting Format
- Option 1 - Contact ID enabled?
t
t
t
t
Domestic
NO
YES
Contact ID
Dialer.
Move on to
Go to
Step 20
Step 21
Client Codes.
Dialer
Options.
1
Contact ID.
Reports to a Central Monitoring Station in Contact ID format via the PSTN Line connection.
2
Domestic Dialer.
Reports to a private telephone with simple tone beeps via the PSTN Line connection.
3
CFSK
Not available in this version
4
Securitel
Reports Securitel via Port 0 or Port 1 (see Section 8 Programming Advanced Features)
8
Dual Reporting
Reports to both of the programmed telephone numbers in Contact ID and/or Domestic Dialer formats.