p30
Ver. 3.604 (31/03/05)
INNER RANGE IQ. PLUS Programmer’s Manual.
No Reporting.
Go to Step 30
“User Programming”
t
t
Domestic Dialer.
Go to Step 21
“Dialer Options”
t
t
20.
PROGRAM THE AREA CLIENT CODE/S.
Area 1 / General Area ................................................................ NEXT 521
Area 2 ........................................................................................ NEXT 522
Area 3 ........................................................................................ NEXT 523
Area 4 ........................................................................................ NEXT 524
Program one or more 4 digit Client Codes. Default for Area 1 is 9999, all other Areas are
blank and will use the value from Area 1 or if required, a unique Client Code may be
programmed for each Area that is to Report. Client Code/s are provided by the Central
Monitoring Station.
Program the Securitel “Hard ID” into the General Area / Area 1 Client Code,
STU or PANEL must be restarted if the value is changed.
Contact ID.
Go to Step 20 Client Codes.
21.
PROGRAM THE DIALER OPTIONS.
NEXT 506
22.
PROGRAM THE GENERAL OPEN/CLOSE AREA LISTS.
NEXT 507
Required only if Dialer Option 5 -“General Open/Close Reporting” selected above.
DEFAULT:
Area 1.
Assign the required Area/s to the General Open/Close Area List: (NOTE: Area 1 must be included in the list)
1 - Include Area 1. (Enabled by Default)
3 - Include Area 3.
2 - Include Area 2.
4 - Include Area 4.
t
t
t
Option
Default
1
Alarms reported via Dialer.
Yes
2
Alarm Restores reported via Dialer.
Yes
3
Isolates reported via Dialer.
Yes
4
Report Open only after an alarm.
No
5
General Open/Close reporting.
No
6
All Area Opens/Closes reported via Dialer.
No
7
System Restores reported via Dialer.
No
How to Enter Data.
Select Address: Key in the Installer PIN Code; Press
then enter the 3 digit Address
(A1 to A3 Lamps will flash to prompt for each digit). The current Data will be displayed.
Enter Data:
Enter the new Data
.. (1-16 digits) OR Option/s to Select/De-select
, then
. NOTE:
clears the current field of all data or settings ready for new data.
Note: When Securitel Reporting is used, the
selected events at 506 will be reported via
Securitel