ABK2027IQE01_A - Installation and Operation Manual
Test
Parameters
Acronym
Description
Units
Defined value
ss
I
rated
Output Current Rating
A
1500 @ 1500 Vdc
1600 @ 1000 Vdc
RR
SS_min
Minimum normal ramp-up rate
%I
rated
/sec
0.1
RR
SS_max
Maximum normal ramp-up rate
%I
rated
/sec
100
I
low
Minimum output current
A
30
MSA
SS
Ramp Rate Accuracy
%I
rated
/sec
2
td
Is dwell time between test iterations as specified by the
manufacturer
s
1
SPF
S
rated
Apparent Power Rating
VA
Rated power
depending on model
P
rated
Output Power Rating
W
Rated power
depending on model
[V
dc_min
, V
dc_max
] DC Input voltage range with function enabled
V
Voltage range
depending on model
[V
ac_min
, V
ac_max
] AC voltage range with function enabled
%V
rated
70
~
120%
MSA
Vac
AC voltage measurement accuracy
%V
rated
1%
MSA
Vdc
DC voltage measurement accuracy
%V
rated
1%
[Plow, Prated] Active power range of function
%
20
~
100%
MSA
PF
Power Factor Accuracy
--
0.01
ts
Power Factor Settling Time
s
2
PF
min,ind
Minimum Inductive (Underexcited) Power Factor
--
0.85
PF
min,cap
Minimum Capacitive (Overexcited) Power Factor
--
0.85
PF
mid,ind
Medium Inductive Power Factor
--
0,925
PF
mid,cap
Medium Capacitive Power Factor
--
0,925
Volt/VAr
S
rated
Apparent Power Rating
kVA
1800
P
rated
Output Power Rating
kW
1800
--
EUT Input Voltage range with function enabled
V
997
~
1500
V
nom
Nominal AC EPS voltage
V
398
[V
min
, V
max
]
AC EPS voltage range with function enabled (V)
%V
nom
82
~
118
MAS
q
Reactive Power Accuracy
%S
rated
2
--
Maximum Ramp Rate
kVAr/s
1800
Q
max, over cap
Maximum Rated Reactive Power Production
(Capacitive, Overexcited)
kVAr (%S
rated
)
948 (52.7%)
Q
max, under ind
Maximum Rated Reactive Power Absorption
(Inductive, Underexcited)
kVAr (%S
rated
)
948 (52.7%)
K
VARmax
Maximum Slope
kVAr (%S
rated
/%V
rated
)
119 (29.34%
S
rated
/%V
rated
)
Deadband
min
Minimum Deadband Range (V)
%V
nom
0
Deadband
max
Maximum Deadband Range (V)
%V
nom
6
t
s
Settling Time
S
2
“Active Power Priority” and “Reactive Power Priority” configurations
YES
FW
P
rated
Output Power Rating
W
Rated power
depending on model
MSA
Hz
Manufacturer’s stated AC frequency measurement
accuracy
Hz
0.1
MSA
P(f)
Manufacturer’s stated P(f) accuracy
%P
rated
2.0
ts
Settling Time
s
2
K
Power-Freq_Max
Maximum slope of frequency droop
%P
rated
/Hz
100
K
Power-Freq_Min
Minimum slope of frequency droop
%P
rated
/Hz
10
Over frequency (*)
[f
min
, f
max
]
AC frequency range with function enabled
Hz
60.0
~
65.0
[f
start_min
, f
start_max
] Adjustment range of the start of frequency droop
Hz
60.0
~
64.0
39
Unit description
Ingeteam
Содержание INGECON SUN 1000TL U B360
Страница 1: ...INGECON SUN PowerMax TL U B 1000 Vdc Installation and Operation Manual...
Страница 22: ...ABK2027IQE01_A Installation and Operation Manual DC supply 22 Unit description Ingeteam...
Страница 176: ...Notes...
Страница 177: ...Notes...
Страница 178: ...Notes...
Страница 180: ...ABK2027IQE01_A 05 2019 Ingeteam Power Technology S A www ingeteam com...