ABK2027IQE01_A - Installation and Operation Manual
6.2. Environment
•
Place the units in a place which is accessible for installation and maintenance work and which permits
use of the keyboard and the reading of the front indicator LEDs.
•
The air vents and part of the power module can reach high temperatures. Do not place any material
nearby which is sensitive to high air temperatures.
•
Avoid corrosive environments that may affect the proper operation of the inverter.
•
Never place any object on top of the unit.
•
It is recommended to protect the units from direct sunlight. Place the units under a cover that protects
them from direct radiation, placing the front part facing north in the Northern Hemisphere and facing
south in the Southern Hemisphere.
6.3. Environmental conditions
Environmental conditions must be taken into account when choosing the location of the unit.
Environmental conditions
Minimum temperature
-4 ºF (-20 ºC)*
Minimum surrounding air temperature
-4 ºF (-20 ºC)*
Maximum operating temperature
140 ºF (60 ºC)
(2)
Maximum relative humidity without condensation
100%
Altitude
14,760 ft (4,500 m)
(3)
(1)
If installing the
Low temperature operating kit
, the minimum operating temperature is -22 ºF (-30 ºC).
(2)
Operation of the inverter at temperatures greater than 122 ºF (50 ºC) should only occur occasionally and not permanently. Ingeteam
is not responsible for the consequences to the unit resulting from operating it at temperatures higher than 122 ºF (50 ºC).
(3)
At altitudes higher than 3300 ft (1000 m), please contact Ingeteam.
It should be borne in mind that moderate condensation may occasionally occur as a consequence of temperature
variations. For this reason, apart from the unit's own protection, it is necessary to monitor these units once they
have been started up on sites where the conditions described above are not expected to be present.
In the event of condensation, never apply voltage to the unit. To remove condensation apply a flow of hot air at a
maximum temperature of 140 ºF (60 ºC).
INFO
Ingeteam does not guarantee the proper operation of the equipment if the operation conditions for which it has
been designed are not fulfilled.
45
Preparation for installing the unit
Ingeteam
Содержание INGECON SUN 1000TL U B360
Страница 1: ...INGECON SUN PowerMax TL U B 1000 Vdc Installation and Operation Manual...
Страница 22: ...ABK2027IQE01_A Installation and Operation Manual DC supply 22 Unit description Ingeteam...
Страница 176: ...Notes...
Страница 177: ...Notes...
Страница 178: ...Notes...
Страница 180: ...ABK2027IQE01_A 05 2019 Ingeteam Power Technology S A www ingeteam com...