ABK2027IQE01_A - Installation and Operation Manual
DC connection via a terminal with two holes
A
B
D
C
B
E
13/4 in
≤
0.39 in
≤
1.3 in
M12
M12
A. M12 hex head bolt.
B. M12 washer.
C. Terminal. Hole diameter of M12, maximum thickness of 0.39 in (10 mm), maximum width of 1.3 in
(33 mm), vertical distance between holes of 13/4 in (44.5 mm).
D. Busbar.
E. M12 nut.
DC connection via two terminals with two holes
A
B
D
C
C
B
E
13/4 in
≤
0.39 in
≤
1.3 in
M12
M12
A. M12 hex head bolt.
B. M12 washer.
C. Terminal. Hole diameter of M12, maximum thickness of 0.39 in (10 mm), maximum width of 1.3 in
(33 mm), vertical distance between holes of 13/4 in (44.5 mm).
D. Busbar.
E. M12 nut.