terminates in a HIROSE plug #HR10A-10P-12S, and has two small BNC pig-tail
cables for the external trigger input (black) and strobe output (white). The
corresponding BNC connector pin mapping is shown on Table 1.4b.
1.4.3 Power Supply
The camera Link version of the camera is compatible with power over camera Link
– PoCL, with a maximum power of 4 W.
If PoCL is not available, a universal desktop power supply adapter, providing +12
VDC, ± 10%, and up to 2.5A constant DC current, is available (for additional price)
from Imperx for the BOBCAT cameras. The operating input voltage ranges from 90
to 240 VAC.
CAUTION NOTE
1.
It is strongly recommended that you do not use an adapter other than the one that
is available from Imperx for the camera!
2.
The PoCL current is limited to 333 mA. The cameras are PoCL compatible in
normal camera operation – free running with full image. In some modes such as
vertical binning x4 and x8 and in AOI (with keep frame rate disabled), when the
vertical height is less than 100 lines, the camera current can exceed 333 mA.