BOBCAT Hardware User’s Manual
Imperx, Inc.
Rev. 2.0.2
6421 Congress Ave.
11/20/2012
Boca Raton, FL 33487
+1 (561) 989-0006
178 of 265
0x2 – double triggering
0x3 – frame accumulation
0x4 – asynchronous triggering
0x5 to 0xF – reserved
Data (31:4)
:
N/A
4.3.9.8
Number of Frames Captured
This register selects the number of frames captured after each trigger signal.
Address
:
0x051C
Data (15:0)
:
<value> – # of frames captured
Data (31:16)
:
N/A
4.3.9.9
Number of Pulses Used
This register selects the number of trigger pulses used during a single trigger
sequence in frame accumulation mode.
Address
:
0x0520
Data (15:0)
:
<value> – # of pulses used
Data (31:16)
:
N/A
4.3.9.10
Trigger Exposure Delay
This register selects the delay between the trigger signal and the beginning of
exposure. The actual exposure can set using “Exposure Time Absolute”
register 0x0548.
Address
:
0x0528
Data (23:0)
:
<value> – exposure delay in microseconds
Data (31:24)
:
N/A
4.3.9.11
Trigger Strobe Enable
This register enables a strobe signal synchronous with the trigger pulse. The
strobe signal is mapped to one or both of the available strobe outputs.
Address
:
0x0524
Data (1:0)
:
00 – no strobe signal
01 – enable Strobe #1
10 – enable Strobe #2
11 – enable Strobe #1 and Strobe #2
Data (31:2)
:
N/A
4.3.9.12
Trigger Strobe Position Delay
This register sets the delay between the trigger pulse and the strobe pulse.
Address
:
0x052C