BOBCAT Hardware User’s Manual
Imperx, Inc.
Rev. 2.0.2
6421 Congress Ave.
11/20/2012
Boca Raton, FL 33487
+1 (561) 989-0006
180 of 265
Data (31:17)
:
N/A
4.3.10.5
Pulse Generator Enable
This register enables the pulse generator.
Address
:
0x0540
Data (0)
:
0 – disable pulse generator operation
1 – enable pulse generator operation
Data (31:1)
:
N/A
4.3.11 Test Pattern Workspace Registers
4.3.11.1
Test Mode Select
This register selects the test mode pattern.
Address
:
0x012C
Data (3:0)
:
0x0 – no test pattern
0x1 – black image – 0x000
0x2 – gray image – 0x1FF
0x3 – white image – 0xFFF
0x4 – steady horizontal image ramp
0x5 – steady vertical image ramp
0x6 – moving horizontal image ramp
0x7 – moving vertical image ramp
0x8 – 8 gray scale vertical bars
0x9 – H & V lines superimposed over live image
0xA to 0xF - reserved
Data (31:4)
:
N/A
4.3.11.2
H & V Lines Superimpose Enable
This register enables the H & V lines superimposed over live image.
Address
:
0x0130
Data (0)
:
0 – disable lines superimposed
1 – enable lines superimposed
Data (31:1)
:
N/A
4.3.11.3
H1 Superimposed Line Position
This register set the position of the horizontal line H1 (top) position.
Address
:
0x0138
Data (11:0)
:
<value> – H1 line position
Data (31:12)
:
N/A