Address
:
0x05AC
Data (0)
:
0 – display active lines only
1 – display all visible lines
Data (31:1)
:
N/A
4.3.6 Exposure Control Workspace Registers
4.3.6.1
Exposure Control Mode
This register sets the exposure control mode and for the camera.
Address
:
0x0544
Data (1:0)
:
00 – off – no exposure control
01 – pulse width – the duration of the selected
trigger pulse determines the exposure during
triggering
10 – internal – exposure control register 0x0548 sets
the camera exposure
11 – external – an external signal via the camera I/O
determines the exposure.
Data (31:2)
:
N/A
4.3.6.2
Exposure Time Absolute
This register sets the actual camera exposure time when “Internal” exposure
mode is selected.
Address
:
0x0548
Data (23:0)
:
<value> – actual exposure time in micro seconds.
Data (31:24)
:
N/A
4.3.6.3
Programmable Line Time Enable
This register enables a programmable line time mode. The user can extend the
camera line time beyond the camera free-running line time. This applies to all
lines in the frame.
Address
:
0x054C
Data (0)
:
0 – disable programmable line time.
1 – enable programmable line time
Data (31:1)
:
N/A
4.3.6.4
Programmable Line Time Absolute
This register sets the actual line time in pixels.
Address
:
0x0554
Data (12:0)
:
<value> – actual line time in pixels.