BOBCAT Hardware User’s Manual
Imperx, Inc.
Rev. 2.0.2
6421 Congress Ave.
11/20/2012
Boca Raton, FL 33487
+1 (561) 989-0006
158 of 265
4.3.2.7
Save to User #2
The
‘Save To User #2’
command instructs the camera to save its
workspace to the user #2 space. All current workspace settings will be saved
to the user #2 space. This is a command, not a register. The act of writing to
this location initiates the save to user #2 space.
Address
:
0x6078
4.3.2.8
SW_Reset
The
‘SW_Reset’
command instructs the camera to initiate software reset,
which resets the camera and loads its workspace from one of the configuration
spaces as determined by the „Boot From‟ data.
Although, this is a command,
the user MUST write a specific data 0xDEADBEEF in order to initiate the
reset sequence.
Address
:
0x601C
Data
:
0xDEADBEEF
4.3.2.9
BAUD Rate Selector
This register sets the communication baud rate between the camera and
computer.
Address
:
0x0604
Data (2:0)
:
000 – 9600
001 – 19200
010 – 38400
011 – 57600
100 – 115200 (default)
Data (31:3)
:
N/A
4.3.3 Retrieving Manufacturing Data
The camera contains non-volatile memory that stores manufacturing related
information. This information is programmed in the factory during the
manufacturing process.
4.3.3.1
Firmware Revision
This register returns the camera main firmware revision.
Address
: 0x6004
Data (31:28)
: <FW image>