BOBCAT Hardware User’s Manual
Imperx, Inc.
Rev. 2.0.2
6421 Congress Ave.
11/20/2012
Boca Raton, FL 33487
+1 (561) 989-0006
199 of 265
Save To:
Saves the camera
registers to File, User Space #1 or User Space #2.
Factory Space is disabled for regular users and it is available only for
manufacturing technicians.
1.
File
– saves the current camera settings to a configuration file
2.
Factory Space
– saves the current camera settings to the camera
Factory space. This is restricted command and is disabled for
regular users.
3.
User Space #1
– saves the current camera settings to the camera
User space 1.
4.
User Space #2
– saves the current camera settings to the camera
User space 2.
Boot:
This menu selects the „Boot From‟ source. Upon power up, the
camera will load its registers from the selected „Boot From‟ source:
Factory, User #1 or User #2. Bobcat camera will be release with
„Factory” Setting and user can save and boot camera with their own
configurable features.
DPM:
Defect Pixel Map – When selected, the DPM window will show
defected pixels location. The defective pixel map is stored in the
camera‟s non-volatile memory and read out when running bad pixel
correction – Figure 5.4. Defected pixels are categorized as:
Figure 5.4 – Defective pixel map
1.
Dead Pixels
– pixels with sensitivity that deviates more than
15% due to fluctuations in the CCD manufacturing process.