BOBCAT Hardware User’s Manual
Imperx, Inc.
Rev. 2.0.2
6421 Congress Ave.
11/20/2012
Boca Raton, FL 33487
+1 (561) 989-0006
209 of 265
Acquisition:
Frames per trigger
– sets the number of frames captured after
each trigger in “Standard” mode. The user can select from 1 to
65500 discrete frames to be captured. If the value is 65501 or
bigger, the camera is free running after the trigger signal.
Pulses per capture
– sets the number of trigger pulses used
during a single acquisition event in “Frame Accumulation”
mode. The user can select from 1 to 65535 discrete pulses.
Exposure Delay:
Sets the delay between the trigger pulse active edge and
beginning of the exposure. The user can set the delay from 0 to
16777215 us.
5.7.4 Pulse Generator
In this window the user can configure the parameters of the Internal Pulse
Generator – Figure 5.13.
Figure 5.13 – Pulse generator window
Granularity:
Sets the granularity for the internal counters. Granularity can be set
to 1x, 10x, 100x or 1000x.
Period
:
Sets the pulse period in microseconds.
Width
:
Sets the pulse width in microseconds.
# of Pulses
:
Sets the number of pulses generated. Two modes are available:
1.
Continuous – provides a continuous operation. To stop the
process you have to press the “Stop” button.
2.
Fixed # of pulses
– the user can set only a discrete number of
pulses ranging (1 to 65500) to be generated. To stop the process