RMV Operations Manual Revision Copyright illunis LLC, 2014
Page 32
04
31
Mode presets – OEM
Write
0x0000 = N/A
0x0001 = Linear LUT
0x0002 = Inverted LUT
0x0003 = Preview LUT
0x0004 = Gamma LUT 0.45
0x0005 = Gamma LUT 0.60
0x0006 = Gamma LUT 0.70
0x0007 = Gamma LUT 0.80
04
32
AE VSYNC Count
R/W
# of frames between AE changes
Set to 3 for free run mode
Set to 1 for triggered modes
04
33
AE Exposure Denominator
R/W
04
34
AE Gain Denominator
R/W
04
35
WB/GNU Tap Select
R/W
0x0000 = left tap (default on power up)
0x0001 = right tap
04
40
FFC table load
W
Activates FFC
04
41
FFC test
W
Loads entire FFC table with data.
Where 0x1000 = 1x, 0x1800 = 1.5x
04
42
FFC Master gain
R/W
Sets FFC master gain
04
43
FFC load mode
R/W
0x0000 = load from com port
0x0001 = load from com port
and save to EEPROM
0x0002 = load from EEPROM
04
04
Mode Register
W
0x0011 = Enable FFC
0x0012 = Disable FFC
Camera Mode and Status
05
00
Camera mode/status
Read
0x0000 = read mode register 1
0x0001 = read mode register 2
0x0002 = read mode register 3
0x0003 = read mode register 4
0x0004 = read mode register 5
0x000B = read mode register 6
0x000C = read mode register 7
0x000D = read mode register 8
0x0007 = read status register 1
0x0008 = read status register 2
0x0009 = read status register 3
0x000A = read status register 4
Camera Configuration
07
00
Read
0x0000 = Camera Model
0x0001 = Camera Hardware rev
0x0002 = Camera Serial Number
0x0003 = Micro firmware rev
0x0004 = FPGA major revision
0x0005 = Sensor Serial Number
0x0006 = Clock Rate
0x0007 = FPGA Sub/minor revision
0x0008 = Micro Sub/minor revision