RMV Operations Manual Revision Copyright illunis LLC, 2014
Page 6
Errata
Auto Tap Match:
If camera is in 1 or 2 tap mode, that matcher will treats the camera as if it were in 4 tap
mode (Micro Version EF.42).
External Trigger In:
The Power Supply board inverts the external trigger from the power connector. The
FPGA did not account for this inversion until EF (Micro Version EF.43).
GigE Support
Not Supported. GigE interface is not fast enough to support 4 tap CCD Readout.
Special Notes
4 Tap Readout:
4 Tap Readout in not four taps to the frame grabber. The RMV camera outputs the
CCD 4 taps on to CameraLink channels running at twice the speed of the CCD pixel clock.
Doing this allows the user to use a frame grabber in base mode (One connector). The user
MUST
be sure the CameraLink cable can support the 80Mhz data rate coming from the cam-
era.
CCD
Camera
Electronics
Frame
Grabber
4 Paths at
40Mhz
2 Paths at
80Mhz