7.4: On Screen Displays
Synthetic Test Patterns
The RMV camera have two synthetic test
patterns that can be used for testing the digital path
and Camera Link communications
.
Serial Commands
Target
Index
Command
R/W Description
04
06
Test Pattern
W
0x0000 = Normal Video
0x0001 = Input (CCD) Test Pattern
0x0002 = Output Test Pattern
Quick FAQ’s:
►The input test pattern can be used to test the inter-
nal data path of the RMV FPGA.
►The Output test pattern can be used to test the
Camera Link digital communication path.
Output Test Pattern
Input (CCD) Test Pattern