RMV Operations Manual Revision Copyright illunis LLC, 2014
Page 97
6.11: Image Detectors
Saturated Pixel Counter
The Brightness detector is used to measure the
brightness of the image within the auto exposure detector
(AED) window. The Saturated Pixel Counter (SPC) is used
to count the number of saturated pixels within the AED win-
dow. The SPC has a maximum value of 16 million pixels.
The SPC represents the top 16bits of a 24 bit counter that
counts pixels whose upper seven bits (of a twelve bit sam-
ple) are all ones.
Serial Commands
Target
Index
Command
R/W Description
04
1a
Read Detectors
R
0x000D = # Sat Pixels
04
1a
Read Detectors
R
0x001D = # Sat Pixels (older version)
03
03
0c
13
AE Detector Data
Top Register Address
R/W Location in units of 16 lines
0x003d = Set AE Top location
03
03
0c
13
AE Detector data
Right Register Address
R/W Location in units of 16 pixels
0x003e = Set AE Right location
03
03
0c
13
AE Detector data
Left Register Address
R/W Location in units of 16 pixels
0x003c = Set AE Left location
03
03
0c
13
AE Detector data
Bottom Register Address
R/W Location in units of 16 lines
0x003F = Set AE Bottom location
Quick FAQ’s:
►The Saturated Pixel Counter (SPC) uses the AE
window as the ROI for measurement.
►The AED window size is programmable.
►The SPC register value must be multiplied by 256
to calcutate the total number od saturated pixels.
►The SPC is useful for determining the set point in
the AE alogrithm.
AED Window
TOP
BOTTOM
LEFT
RIGHT