![background image](http://html1.mh-extra.com/html/illunis/rmv-11002/rmv-11002_operation-manual_2044107013.webp)
RMV Operations Manual Revision Copyright illunis LLC, 2014
Page 13
The RMV EF Revision uses Truesence CCD sensors with a four tap outputs for-
mat. The sensors can be used with either the single, dual or four taps readout
modes.
The 4 tap sensor layout is shown below as displayed by the frame grabber.
When the camera is in single tap mode, all sensor data is clocked out tap A. Sensor
data is clocked out of taps A and B in dual tap mode. In four tap mode the data is
clock out each tap.
For information on setting up the frame grabber, see the frame grabber section of
this document.
Top Black Rows
Top Bufer Rows
Bottom Buffer Rows
Bottom Black Rows
Left Black
Left Buffer
Left Dummy
Right Black
Right Buffer
Active Imaging Area
Tap A
Tap B
Tap C
Tap D
Taps A and C
Taps B and D