RMV Operations Manual Revision Copyright illunis LLC, 2014
Page 100
7.0: On Screen Displays
Overview
The eRugged nature of the RMV name comes in part from the cameras ability to display perfor-
mance and image data as on screen overlays. The RMV FPGA contains circuits that can do the follow-
ing:
Display On Screen Text with:
Programmable character font.
128x32 character screen memory.
Screen memory can be positioned anywhere on image.
Text can be normal or double size.
Text can have transparent or opaque backgrounds.
Display a plot of video data with:
Horizontal (line plot) or Vertical (column plot) display.
Selectable line/column of interest for display.
Selectable baseline position for the plot data.
Scalable plot size from 1 pixel to full scale (4095).
Plot can be drawn as a single line or as a bar plot.
All data can be plotted, including the over scan areas.
In addition to the on screen displays the RMV has several image detectors that are used to calculate
performance data in real time. The data is analyzed and displayed using the On Screen Text feature.
The following screen image shows some of the on screen functions in operation.