no. 67 Lubrication stop value (L) (Parameter Off)
This parameter value should be entered.
Value where the oil pump motor for the
lubrication of the guide channels stops.
no. 68 Guide channel opening max. value
The value of this parameter is predefined by the
program.
Position of the feeding carriage when the guide
channels open.
67
no. 67 Lubrication stop value (L)
mm
DEFAULT VALUE
PROGRAMMABLE VALUE
Kid 80
Kid 80
2380
32 N=2710 L=2380
LL=2050
37 N=3250 L=2920
LL=2590
44 N=3910 L=3580
LL=3250
68
no. 68 Guide channel opening max. value
mm
DEFAULT VALUE
PROGRAMMABLE VALUE
Kid 80