2 - INFORMATION FOR USE
KID 80 SIV
EN
2 - Pag. 63 / 71
5 - ERROR: SHORT FEEDING
Error: A BAR PUSHER SHORT FEEDING MOVEMENT HAS BEEN DETECTED IN ACCORDANCE
WITH THE SETTINGS OF PARAMETERS 5 and 6.
CAUSE SOLUTION
5
Warning
Short feeding
The tolerance values of parameters
5 and 6 are too low.
Check the tolerance values with
regards to the length of the piece to be
machined.
The lathe collet does not open
correctly.
Check the correct opening of the collet
(at least 0.5 mm).
Encoder operation failure.
Check the value relative to the position
of the bar pusher carriage on the
display and check the effective variation
of the value with regards to the real
displacement of the carriage.
The thrust received by the bar is
too low.
Check the values of parameters 7, 8
and 34.
"A" - Short piece safety
tolerance (subparameter
Par.5), Short feeding
safety (subparameter
Par.6).
"C" - Headstock stroke
(Parameter Par.5).
Feeding (Parameter
Par.6).
The bar slides out of the collet
during the headstock stroke.
Check the bar pusher collet state.