2 - INFORMATION FOR USE
KID 80 SIV
EN
2 - Pag. 55 / 71
no. 44 Axis operation
Subparameters:
A - Bar pusher stop with closed collet
B - Axis stop engagement delay
C - Closed collet torque
The subparameters of this parameter control
some functions of the bar pusher movement.
Bar pusher stop with closed collet - Axis
stop engagement delay
These two subparameters enable the feeding
motor stop (axis stop) with CLOSED COLLET, so
as to avoid that the bar slides off from the bar
pusher collet, due to the machining vibrations.
INFORMATION
The function of these two
subparameters is applicable with
parameter 24 in modes 0 and 5. It is not applicable with modes 1, 2, 3 and 4.
Bar pusher stop with closed collet
0 - the bar pusher stop is off
1 - the bar pusher stop is on
Axis stop engagement delay
This subparameter allows setting a delay time for the axis stop engagement at every CLOSED
COLLET. This period of time allows you to "release" the bar feeder transmission devices, so as
to avoid useless tensions.
Closed collet torque
This subparameter allows adjusting the thrust value with which the bar pusher moves the bar
during the "CLOSED COLLET" signal.
44
no. 44 Axis operation
Bar pusher stop
OFF
with closed collet
Axis stop engagement
1 sec
delay
Torque
+20 Cmax
with closed collet
DEFAULT VALUE
PROGRAMMABLE VALUE
Kid 80
Kid 80
OFF ON/OFF
1 /
+20 /
Содержание KID 80 IV Touch
Страница 2: ......
Страница 4: ......
Страница 7: ...1 BASIC INFORMATION KID 80 SIV EN 1 Pag 1 7 INDEX 1 1 Control description 3 ...
Страница 14: ......
Страница 23: ...2 INFORMATION FOR USE KID 80 SIV EN 2 Pag 9 71 2 7 PARAMETER ACCESSING AND DISPLAY ...
Страница 86: ......
Страница 101: ...3 INFORMATION FOR SET UP KID 80 SIV EN 3 Pag 15 23 ...
Страница 110: ......