3 - INFORMATION FOR SET UP
KID 80 SIV
EN
3 - Pag. 17 / 23
no. 72 Speed reduction during bar change
Defines the speed value by which the bar
pusher moves during the bar change cycle in
the phases described by B, C, D, E
subparameters. This value is expressed as a
percentage of the maximum speed.
Parameters:
A - Speed reduction during bar change
Subparameters:
B - From collet entry slowdown to pulse
window end
C - Pulse backwards
D - Facing to limit stop
E - Facing jog
no. 73 Limitation of automatic speed
Defines the speed value by which the bar
pusher moves in automatic mode. This value is
expressed as a percentage of the maximum
speed.
Parameters:
A - Limitation of automatic speed
Subparameters:
B - Collet closed
C - Collet open
72
no. 72 Speed reduction during bar change
CURRENT VALUE
Vmax
From "Collet entry slowdown" to "pulse window end"
Vmax
Pulse backwards
Vmax
Facing to the limit stop
Vmax
Facing jog
Vmax
DEFAULT VALUE
PROGRAMMABLE VALUE
Kid 80
Kid 80
A /
/
B 6
/
C 20
/
D 10
/
E
28
/
73
no. 73 Limitation of automatic speed
CURRENT VALUE
Vmax
Closed collet
Vmax
Open collet
Vmax
DEFAULT VALUE
PROGRAMMABLE VALUE
Kid 80
Kid 80
A /
/
B 20
/
C 30
/
Содержание KID 80 IV Touch
Страница 2: ......
Страница 4: ......
Страница 7: ...1 BASIC INFORMATION KID 80 SIV EN 1 Pag 1 7 INDEX 1 1 Control description 3 ...
Страница 14: ......
Страница 23: ...2 INFORMATION FOR USE KID 80 SIV EN 2 Pag 9 71 2 7 PARAMETER ACCESSING AND DISPLAY ...
Страница 86: ......
Страница 101: ...3 INFORMATION FOR SET UP KID 80 SIV EN 3 Pag 15 23 ...
Страница 110: ......