IDS X  Series Training V2.3 | Standard Master User Functions 

75 

 

Alarm Memory 

The alarm memory will hold information from the last time it was armed. When the alarm is armed again 
the memory clears and will store information from that alarm system arm period. 
The alarm memory holds information on: 
2.

 

Violated zone  

a.

 

Zones that triggered while the system was armed 

3.

 

Bypassed  zones 

a.

 

Zones that where bypassed when the system armed, making them ineffective.  

4.

 

Tampered zones 

a.

 

Zones that someone may have opened and messed about with to stop it functioning 

correctly. 

5.

 

Event log 

a.

 

This is a history of all system messages, going back a thousand events. Once the system 

reaches the thousandth event it will start over writing from the oldest event. 

 
 

 
 
 
 
 
 
 
 
 

User Codes 

1.

 

128 user codes can be programmed into the system. 

2.

 

The  only  code  pre-programmed  into  the  system  is  User  1  which  is  a  master  code,  and  it  is 

defaulted to 1234. 

a.

 

A master code is the administrator of the system, which can do the following. 

i.

 

Add and delete users  

ii.

 

Configure user settings 

iii.

 

Set the time and date  

iv.

 

Teach remote transmitters to a user code 

 

Standard Master User Functions 

The master menu is for administering the system by adding, deleting users, adding remote transmitters, 

etc. 
To access the master menu press and hold the [*] key until the beep, about 3 seconds, then enter the 

master code [1][2][3][4] followed by the [*] key. 
 

Explanation 

Key Presses 

Press and hold the [0] bypass key until the beep 

[0]  

The violated zones will be displayed 

 

Press the [2] for bypassed zones or the [3]  key 
for tampered zones or the [6] key for the event log 

Option 

Description 

Violated Zones 

Bypassed Zones 

Tampered Zones 

Event Log 

 

When complete press the [#] key 

[#] 

Options 

Summary of Programmable Options 

Option 0  Allows for the addition of new user codes. 
Option 1  Allows for the editing of a selected user code. 

 

Option 2  Allows for the deletion of user codes.

 

Option 3  Allows for the adding/editing of slots. 
Option 4  Allows for the deletion of a user code using the user code slot number. 
Option 5  Allows for the viewing of the user code slot number for a selected code.  

Option 10  Allows for the editing of the user code properties for a selected user code.  
Option 11  Allows for the allocation of a selected user code to a designated partition(s).  
Option 13  Allows for the editing of user outputs. 

Содержание X16

Страница 1: ...Multi Language with Wireless Installer Training Firmware Version 2 3 X16 Stock Code 860 1 473 X16 X64 Stock Code 860 1 864 XS Training Manual...

Страница 2: ...2 Contents IDS X Series Training V2 3...

Страница 3: ...________________ 35 Wireless ______________________________________________________________________________________________ 38 Reporting Codes _________________________________________________________...

Страница 4: ...wer supply 9 Programmable zone loop response 10 Up downloadable via software 11 Fax defeat to bypass fax answering machines 12 Optional tamper reporting per zone 13 Non volatile memory 14 Voice report...

Страница 5: ...e alarm will power up automatically 2 Default button 3 Panel Status LED To default the panel physically remove power from the unit and press down the default button Replace power whilst still holding...

Страница 6: ...more detailed information can be found at the end of the manual in appendix 1 Please note that devices especially between different manufacturers are different and the manuals should be thoroughly re...

Страница 7: ...s the same as the onboard programmable outputs except that it triggers with 5V and not 12V The zone works exactly like a normal zone with an end of line resistor When using the zone it will replace th...

Страница 8: ...e X Series first get both PIR heads to detect movement then press the tamper switch when in location 260 sub location 1 and the correct zone number has been selected Dip Sw Function Enable Disable Des...

Страница 9: ...n selected Duevi Outdoor E Wall with PIR Microwave 866 DX EWF Note To learn the door contact to the X Series press the tamper switch when in location 260 sub location 1 and the correct zone number has...

Страница 10: ...13 1000 14 2000 15 4000 16 8000 Hundreds Zone Value 9 100 10 200 11 400 12 800 Tens Zone Value 5 10 6 20 7 40 8 80 Zone Value 3 4 6 20 9 100 Total 124 Zone Value 1 1 4 8 Total 9 Enter Key The key has...

Страница 11: ...nd zone 4 8 12 16 have a value of 8 H Hour m minutes s seconds Value 1 2 4 8 m m s s H H m m Example Programming Installer Mode Installer mode is where all program settings can be changed to suit any...

Страница 12: ...ta value that needs to be in the location followed by the key 4 You can enter the next location or press the key to exit Installer mode Programming Extended Locations Sub location Method The sub locat...

Страница 13: ...l come on if it was off or go off if it was on 5 On the LCD keypad when the key is pressed you will be taken to the option you have chosen This will show you the current value and if you want to then...

Страница 14: ...wireless zones and settings Exercise Defaulting back to factory settings Location 1 to 8 Zone Type Location Type Extended Sub Location Can be programmed using the string method Loc Zone Types 1 Z1 Z2...

Страница 15: ...of a Priority zone will cause the control panel to register a panic condition This zone type CANNOT be bypassed 04 INSTANT ZONE When the panel is armed the violation of an Instant zone will cause the...

Страница 16: ...5 1 5 0 3 d Programming zones 7 and 8 using the sub location method Instructions Key presses Enter location 1 1 Enter the sub location number for zone 7 and press the key 7 Enter the value for an ext...

Страница 17: ...mber of violations must happen in the time set If this does not happen the system will reset both Cross zone delay time is the time that the violations must take place within before a violation is tri...

Страница 18: ...tamper monitoring This looks for a load on the siren port if the load goes missing then a tamper is triggered and logged If option 4 in location 571 is enabled a tamper will be sent to the monitoring...

Страница 19: ...r some sort of trouble that causes the 12V output to fail 7 OFF Engineer s reset trouble display If this option is set in partition options location 211 to 218 and the alarm triggers this option will...

Страница 20: ...ne Supervision This option enables or disables wireless supervision failures from triggering alarms Supervision monitors the wireless devices to make sure that they remain communicating with the syste...

Страница 21: ...888888 Master User Code 1 1234 123456 User Codes 2 128 XXXX XXXX00 Valid Range 4 or 6 Default 4 Location 24 Account Code Number of Digits Location Type Standard The reporting account codes can be inc...

Страница 22: ...ober 2 February 7 July 11 November 3 March 8 August 12 December 4 April Location 29 Day of the Week to End Daylight Savings Location Type Standard Select the day that daylight savings ends Value 1 2 3...

Страница 23: ...ult Disable Location Type Standard The download code is a security code to stop any illegal connection and changing of data via external connections using IDSwift software If this option is enabled th...

Страница 24: ...rmats their event reporting codes are automatically entered into reporting locations Locations 501 to 588 enable or disable reporting for Contact ID and SIA All other formats the reporting codes must...

Страница 25: ...try the second number and go back to the first after it has succeeded with the second number Split reporting is when certain events are programmed to report to certain groups of phone numbers and each...

Страница 26: ...he telephone number the serially connected device must dial to report any signals Note This option is only entered if the serial device has this option built in Location 61 to 68 Primary Account Codes...

Страница 27: ...the user menu 6 ONOFF Zone Bypassable Enable or disable the zone from being bypassed 9 Profile 1 10 Profile 2 11 Profile 3 12 Profile 4 OFF Stay Profile This is to allocate the zone to a stay profile...

Страница 28: ...ered here in the 24 hour format HHMM is when the system will start to monitor for no movement Format HHMM Default 0000 Valid range 0000 to 2359 Location 167 No movement auto arm stop time Location Typ...

Страница 29: ...movement auto arm and no movement alarm days of the week LED ARM Days of the Week LED Alarm Days of the Week 1 Monday 9 Monday 2 Tuesday 10 Tuesday 3 Wednesday 11 Wednesday 4 Thursday 12 Thursday 5 F...

Страница 30: ...must be set Location 190 Auto Delay Location Type Standard This location sets the delay period for the keypad buzzer warning before the panel auto arms At the completion of the Auto Arm Delay the pane...

Страница 31: ...settings using the location method as an Installer would Note No settings can be changed that would compromise communication with the security company Panel functions that can be edited in maintenance...

Страница 32: ...on 201 2 0 2 The green READY LED should be on the and ARM AWAY and POWER LEDs should be off This is a bitmapped location so data is entered by entering the zone number of the zone you want to allocate...

Страница 33: ...zones 8 ON Zone Bypassing This enables or disables the ability for a user to bypass faulty zones using the 9 key 9 OFF Arm with Zones in the Entry Route Violated This allows movement to take place in...

Страница 34: ...is armed and has communicated that to the security company successfully 7 OFF Stay zone reporting When enabled and stay closing is enabled all zones bypassed will be reported to the security company...

Страница 35: ...d default all the keypad s LEDs will flash By pressing the key the keypad will ask the system for an ID The first available ID will be given to the keypad To clear the keypad ID hold down the 1 and 3...

Страница 36: ...4 Exercise Instructions Key presses If not in installer mode enter into installer 9 9 9 9 To enable the keypad zone go to location 242 2 4 2 Again we are only changing keypad 3 so we will use the bitm...

Страница 37: ...e keypad will switch all its LEDs off after the time programmed into location 22 Press any key to wake it up 3 OFF Global keypad status If this is enabled the keypad can view any partition on the syst...

Страница 38: ...output 2 supervision loss 2 Default The second operation is a standalone default feature If all Dip switches are ON during power up then the unit will default Please power down after set appropriate...

Страница 39: ...Armed LED ON Away LED flashing b Menu system now only awaiting sub location selection i User must enter number to advance into sub menu c When entering sub menus I e add wireless device or delete wir...

Страница 40: ...ia keypad by a LONG OK beep as well as the Zone LED previously flashing will now be ON 3 The system will now wait for a new zone to be selected 4 key at any time will return the user back to the sub m...

Страница 41: ...location 260 and scrolling to or entering option 2 the following will be displayed Scroll using Medical or Panic Keys Enter with key 1 Enter to enter the delete sub location to have the following disp...

Страница 42: ...n entering location 260 and entering option 4 the following will be displayed 3 Hr Check in 12 Hr Check in Flashing 1 Enter the supervision time required by entering the correct option from the follow...

Страница 43: ...is sent 4 Communication Restored When communication is restored the code is sent 5 Phone line tamper If the phone line is tampered with and the line voltage goes missing an alert is sent 6 Phone line...

Страница 44: ...1 Wireless detector supervision failure Each device checks in with the controller at a predetermined time and if this signal is not received the alarm company is alerted that it has gone missing 2 Wir...

Страница 45: ...he contact ID reporting code for each zone to extend what can be connected to each zone and what is reported to the control room Example If a gas detector is connect to zone 8 By entering 26 into loca...

Страница 46: ...on Type Extended There is a sub location for each of the 8 partitions These reporting codes are sent when someone away arms the system using the quick arm key 1 Location 375 Quick Stay Reporting codes...

Страница 47: ...n must also be entered so that the system knows what to do when triggered The action can be either a pulse or latch as discussed before Below are the values for the actions Value Output Action ACTION...

Страница 48: ...on a zone and the tamper switch on the device is triggered 398 Zone Tamper Restoral Programmable Output When the tamper switch goes back to normal 399 Zone Shutdown Programmable Output If enabled and...

Страница 49: ...ill only trigger when the system is armed but a 24 hour zone is always active therefore even if the system is unarmed and the zone is triggered the output will trigger Location 415 to 422 Zone trigger...

Страница 50: ...send a signal either every 90min or 12 hours to confirm it is still available If the system does not receive the signals a supervision fail is logged 4 RF Detector Battery Low When the wireless devic...

Страница 51: ...ocation Type Extended This location has 5 sub locations representing Ooutputs 1 to 5 on the main system board Installer Code 4 4 8 Output No h h m m Data format hhmm Valid Range 0000 2359 2400 disable...

Страница 52: ...tion Default 1 ON Zone alarm reporting If this option is selected whenever a zone is violated the alarm reports via telephone 9 OFF 2 OFF Zone alarm restore When the zone restores the alarm reports vi...

Страница 53: ...nal drops below 20 a message will be sent to alert the security company 15 OFF 8 ON AC Restored After AC is restored a message can be sent 16 OFF LED Default Action Explanation Split Reporting Option...

Страница 54: ...ng Location Type Bitmap LED Default Action Explanation Split Reporting Option Default 1 OFF Bus device comms restored When a device has stopped communicating on the bus and when the fault is corrected...

Страница 55: ...a fire zone and is violated a fire signal is sent to the security company 11 OFF 4 ON Medical Reporting When the M key or the option Medical alarm if no movement is detected is enable a medical signal...

Страница 56: ...company 2 ON Stay Close Reporting Enable if a stay close signal is to me sent 3 ON Open Reporting Enable if a open signal is to me sent 4 OFF Siren Cancel Reporting Enable if the siren is active and a...

Страница 57: ...6 Local printer failure Zone 1B 138 Near alarm Zone 56 337 Exp Module DC Loss Zone 1C 139 Intrusion Verifier Zone 57 338 Exp Module Low Batt Zone 1D 140 General Alarm Zone 58 339 Exp Module Reset Zone...

Страница 58: ...Error user User C4 604 Fire test User 8F 458 User on Premises User C5 605 Status report to follow Zone 90 459 Recent Close User C6 606 Listen in to follow Zone 91 461 Wrong Code Entry Zone C7 607 Wal...

Страница 59: ...OFF Off Bus wired peripheral tamper monitoring 11 OFF OFF Onboard dedicated panic silent 12 ON ON Low battery monitoring 13 ON ON Low battery cut out 14 OFF OFF Bypassing with user code 15 OFF OFF Ded...

Страница 60: ...orting Locations 342 349 Close Reporting Codes Clears all codes Locations 350 357 Stay Close Reporting Clears all codes Locations 358 365 Open Reporting Clears all codes Locations 366 373 Siren Cancel...

Страница 61: ...heral fail reporting 10 OFF Telephone module 1 3 OFF OFF Bus wired peripheral low battery reporting 11 OFF Telephone module 1 4 ON OFF Wireless Detector Battery Low 12 OFF Telephone module 1 5 OFF OFF...

Страница 62: ...ON Test Report 16 OFF Telephone module 1 Location 575 Global Split Reporting 5 LED Factory Default Default 5 Action LED On Off Reporting Pair 1 OFF OFF IDSwift Download Accessed 9 OFF Telephone module...

Страница 63: ...ON OFF Enable box tamper monitoring 9 ON OFF Enable siren monitoring 10 OFF OFF Disable bus wired peripheral tamper monitoring 11 OFF OFF Disable onboard dedicated panic audible 12 ON ON Enable low b...

Страница 64: ...orting Locations 342 349 Close Reporting Codes Clears all codes Locations 350 357 Stay Close Reporting Clears all codes Locations 358 365 Open Reporting Clears all codes Locations 366 373 Siren Cancel...

Страница 65: ...Telephone module 1 2 ON OFF Enable bus wired peripheral fail reporting 10 OFF Telephone module 1 3 OFF OFF Disable bus wired peripheral low battery reporting 11 OFF Telephone module 1 4 ON OFF Wirele...

Страница 66: ...nic 15 OFF Telephone module 1 8 ON OFF Test Report 16 OFF Telephone module 1 Location 575 Global Split Reporting 5 LED Factory Default Default 6 Action LED On Off Reporting Pair 1 OFF OFF IDSwift Down...

Страница 67: ...ry route violated 12 Entry beep 13 Exit beep Page 25 221 to 228 1 Automatic enabling of shutdown zones 2 Bypassing common zones 7 Stay zone reporting 8 Zone restoral signal sending option Page 26 241...

Страница 68: ...57 Keypad output scheduling Page 41 572 1 Bus wired peripheral tamper reporting 2 Bus wired peripheral communication fail reporting Page 43 573 8 Bus wired peripheral tamper restore reporting Page 43...

Страница 69: ...ireless device supervision time Page 30 302 to 303 Global split reporting options Page 35 304 to 335 Zone reporting Page 35 415 to 422 Zone triggered outputs Page 40 425 Wireless triggered outputs Pag...

Страница 70: ...70 User Menu IDS X Series Training V2 3 Multi Language with Wireless User Menu Firmware Version 2 3 X16 Stock Code 860 1 473 X16 X64 Stock Code 860 1 864 XS Training Manual...

Страница 71: ...confirm entry and save information 2 Hold until beep enter master user code and choose menu option 3 In dealing with options that have zone selections the LED keypad can only show 16 zones at a time T...

Страница 72: ...exit zone 2 Enter a user code the exit delay will begin and exit via an entry exit zone Eg 2 3 3 2 NOTE If the entry exit zone is not triggered the system by default will automatically arm in the stay...

Страница 73: ...by zone 3 etc 1 8 1 0 1 5 When complete press the key Toggling between the 2 stay profiles can be done in three ways 1 Toggle method Note only if there is more than one profile with stay zones a Pres...

Страница 74: ...ess and hold the 2 chime zone key until the beep 2 Enter each zone to be a chime zone until complete for zones 1 to 16 4 6 1 1 To access zones 17 to 32 press the key Now zone 17 is represented by zone...

Страница 75: ...te iv Teach remote transmitters to a user code Standard Master User Functions The master menu is for administering the system by adding deleting users adding remote transmitters etc To access the mast...

Страница 76: ...seconds Enter the master code followed by the key 1 2 3 4 Enter the value to delete a user code followed by the key 2 Now enter the user code to be deleted followed by the key 5 8 7 9 When complete pr...

Страница 77: ...to any partition Example Instruction Key presses Press and hold the key for 3 seconds Enter the master code followed by the key 1 2 3 4 Enter the value to delete a user code via a slot number followe...

Страница 78: ...t 2 01 Onboard output 1 14 Zone expander 5 output 1 02 Onboard output 2 15 Zone expander 5 output 2 03 Onboard output 3 16 Zone expander 6 output 1 04 Onboard output 4 17 Zone expander 6 output 2 05 O...

Страница 79: ...ay pulse time Option 26 Allows for the defaulting of the receiver Option 27 Allows for the identification of the receiver Option 28 Allows for the testing of the receiver Option 29 Allows for the view...

Страница 80: ...add remotes using the advanced method followed by the key 2 1 Enter the remote receiver ID that the transmitter will be taught to followed by the key 1 Now enter the user code followed by the key 2 3...

Страница 81: ...l rest in normally open 2 Panic When a panic is triggered via a button or the 3 second hold option the relay will trigger 3 Retrigger This stops the relay from retriggering for 20 seconds after an ini...

Страница 82: ...ction Key presses Press and hold the key for 3 seconds Enter the master code followed by the key 1 2 3 4 Enter the value to default the remote receiver followed by the key 2 6 Enter the remote receive...

Страница 83: ...rd Approx 3 seconds Options Summary of Programmable Options Option 40 Allows for the editing of the time Option 41 Allows for the editing of the date Instruction Key presses Press and hold the key for...

Страница 84: ...r off via the keypad Mode 3 Output Alarm Memory Alarm memory holds information on zones that triggered tampered with and bypassed for the arm cycle that has just been disarmed Once the system arms aga...

Страница 85: ...iolated Zone Violated New Partition Menu on LCD keypads When entering quick arm stay arm or stay go and the option is enabled all partitions will be shown with their status Menu status options i r rea...

Страница 86: ...ion is triggered the alarm can only be armed again once the installer code has been entered 8 Box tamper The panel has pins to connect a switch that can monitor if the box is opened 9 Peripheral Devic...

Страница 87: ...nt No Press RT Button Delete Remote Master Code 2 2 Receiver No User Code Button Properties Master Code 2 3 Receiver No Button No Properties Relay Properties Master Code 2 4 Receiver No Relay No Prope...

Отзывы: