16
Global Settings | IDS X Series Training V2.3
1.
Programming zones using both the string and bitmapped methods.
a.
Let‟s program zones 9 to 16 using the string method and zones 17 to 24 using the
bitmapped sub-
locaton
method
b.
The table describes what type of zone each one will be
Zone
Type
Value
Zone
Type
Value
9
Secondary Entry / Exit
08
17
Entry / Exit
01
10
Follower
02
18
Follower
02
11
Follower
02
19
Instant
04
12
Instant
04
20
Instant
04
13
Instant
04
21
Follower
02
14
Outdoor Instant
15
22
Follower
02
15
Outdoor Instant
15
23
Outdoor Instant
15
16
Panic
03
24
Panic
03
c.
To program zones 9 to 16 into the system via the string method:
Instructions
Key presses
Enter installer mode
[#] [9] [9] [9] [9] [*]
Enter the location 2
[2] [*]
Type in the complete string of information for all
zones
[0][8] [0][2] [0][2] [0][4] [0][4] [1][5] [1][5] [0][3] [*]
d.
Programming zones 7 and 8 using the sub-location method:
Instructions
Key presses
Enter location 1
[1] [*]
Enter the sub-location number for zone 7 and press the
[*]
key
[7] [*]
Enter the value for an external instant zone followed by the
[*]
key.)
[1] [5] [*]
Now zone 8
[8] [*]
Panic zone
[0] [3] [*]
To exit location 1 press the
[#]
key
[#]
Note: You will still be installer mode
Global Settings
Location 10: Zone Shutdown Count
Location Type: Standard
This option monitors the zone for the number of times it violates when the system is armed. Once the
number of violations reaches the number entered in this location, the zone is automatically bypassed.
Each partition has an option to enable any zones belonging to the partition that were bypassed due to this
option in locations 221 to 228 depending on the partition.
Valid Range: 1 - 15
Default: 5
Location 11: Programmable Zone Loop Response Time
Location Type: Standard
This is the time that the zone must be violated before the zone will register a violation.
Valid Range: 1 - 255
Default: 2