IDS X Series Training V2.3 | Daylight Savings
21
Location 22: Keypad Sleep Delay
Location Type: Standard
If the keypad is set in location 251 to 258, depending on the keypad‟s ID, to go into sleep mode, this
location is how long after the last key press does the keypad wait to switch of all its LEDs.
Data format: mmss
Valid Range: 0001 - 5959
Default: 0500
Location 23: User, Installer, Maintenance Code Number of Digits
Location Type: Standard
By default all codes are made up of four digits. This location can change the number of digits that make
up a code to six digits.
If the number of digits is changed to six, then:
Code
Old four-digit
code
New six-digit
code
Installer Code
9999
999999
Maintenance Code
8888
888888
Master User Code 1
1234
123456
User Codes 2-128
XXXX
XXXX00
Valid Range: 4 or 6
Default: 4
Location 24: Account Code Number of Digits
Location Type: Standard
The reporting account codes can be increased to six digits from four.
Valid Range: 4 or 6
Default: 4
Daylight Savings
Daylight savings is practiced in some countries in summer where they advanced their time to increase
daylight in the evenings and back in autumn.
Location 25: Month to Start Daylight Savings
Location Type: Standard
Select the month that daylight savings begins
Value
Month
Value
Month
Value
Month
0
Disabled
5
May
9
September
1
January
6
June
10
October
2
February
7
July
11
November
3
March
8
August
12
December
4
April
Location 26: Day of the Week to Start Daylight Savings
Location Type: Standard
Select the day that daylight savings begins
Value
1
2
3
4
5
6
7
Day
Monday Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Содержание X16