24
Communication Settings | IDS X Series Training V2.3
Location 37: Zone Status Verify Count
Location Type: Standard
The number of times a burglary event will be sent if the zone does not restore once the siren times out.
After the number in this location is reached the zone will be ignored until it restores.
Valid Range: 0 to 16
Default: 0
Communication Settings
Location 40: Serial Communication Format
Location Type: Standard
This is to configure the X-Series alarm system to communicate to the serial device using the correct format
Note: For serial communication jumper J1 must be shorted / closed.
J1 open = direct download enabled; closed = serial reporting
Location 41 to 44: Communication format
Location Type: Standard
This is the language the Alarm Panel must transmit for the equipment in the control room to understand
what is being reported. Each phone number can be enabled to communicate in a different format.
Note: For Contact ID and SIA formats, their event reporting codes are automatically entered into
reporting locations. Locations 501 to 588 enable or disable reporting for Contact ID and SIA.
All other formats, the reporting codes must be entered manually into location 300 to 373.
Location 45: Communication Delay
Location Type: Standard
This is the time the alarm will wait before reporting an event; it must be enabled under partition options in
locations 221 to 228.
Data Format: mmss
Valid Range: 0001 to 5959
Default: 0000
Value
Format Name
Description
0
Ademco Express
Dual Tone HS, DTMF
1
FBI 4 x 2 ( With Parity)
1.8kHz TX, 2.3kHz HS, 40PPS
2
FBI 4 x 2 (No Parity)
1.8kHz TX, 2.3kHz HS, 20PPS
3
Silent Knight 4 x 2 Fast 1.9kHz TX, 1.4kHz, 20PPS
4
Silent Knight 4 x 2 Slow 1.9kHz TX, 1.4kHz, 20PPS
5
Contact ID
Dual Tone HS, DTMF
7
SIA Reporting
Bell 103 FSK, HS
Value
Format Name
Description
0
Ademco Express
Dual Tone HS, DTMF
1
FBI 4 x 2 ( With Parity)
1.8kHz TX, 2.3kHz HS, 40PPS
2
FBI 4 x 2 (No Parity)
1.8kHz TX, 2.3kHz HS, 20PPS
3
Silent Knight 4 x 2 Fast 1.9kHz TX, 1.4kHz, 20PPS
4
Silent Knight 4 x 2 Slow 1.9kHz TX, 1.4kHz, 20PPS
5
Contact ID
Dual Tone HS, DTMF
7
SIA Reporting
Bell 103 FSK, HS
Содержание X16