74
Standard User Functions | IDS X Series Training V2.3
Buzz Zone
A buzz zone is only active during stay arms. It is a zone that when violated, when the system is stay
armed, will buzz the keypad for 30 seconds before sounding the alarm.
How to setup buzz zones.
Explanation
Key Presses
Press and hold the [4] buzz zone key until the beep [4]
Enter each zone to be a buzz zone until complete
for zones 1 to 16
[1] [*] [2] [*] [8] [*]
To access zones 17 to 32 press the [*] key
[*]
Now zone 17 is represented by zone 1, 18 by 2, 19
by zone 3, etc.
[1] [*] [5] [*] [1] [0] [*] [1] [5] [*]
To access the next 16 zones press the
[*]
key, and
add the zones as needed
[*]
When complete press the [#] key
[#]
Chime Zone
A chime zone is a zone that will beep all keypads 5 times when a zone is violated in the unarmed state.
How to create chime zones:
Explanation
Key Presses
Press and hold the [2] chime zone key until the beep
[2]
Enter each zone to be a chime zone until complete for zones 1 to 16
[4] [*] [6] [*] [1] [1] [*]
To access zones 17 to 32 press the [*] key
[*]
Now zone 17 is represented by zone 1, 18 by 2, 19 by zone 3, etc.
[1] [3] [*] [1] [4] [*] [1] [6] [*]
To access the next 16 zones press the [*] key, and add the zones as
needed
[*]
When complete press the [#] key
[#]
Bypassing Zones
If a zone is faulty and is preventing the system from being armed it can be bypassed. To bypass zones
you must enter a user code.
Explanation
Key Presses
Press and hold the [9]
bypass key until the beep
[9]
Enter a [USER CODE]
followed by the
[*]
key
[1] [2] [3] [4] [*]
Enter each zone to be bypassed until complete for zones 1 to 16
[4] [*] [6] [*] [1] [1] [*]
To access zones 17 to 32 press the [*] key
[*]
Now zone 17 is represented by zone 1, 18 by 2, 19 by zone 3, etc.
[1] [3] [*] [1] [4] [*] [1] [6] [*]
To access the next 16 zones press the
[*]
key, and add the zones as
needed
[*]
When complete press the [#] key
[#]
The zone LED will be on
Panic zones can be bypassed if enabled in zone options location 101 to 164
Содержание X16
Страница 2: ...2 Contents IDS X Series Training V2 3...