Programmable Serial-to-Ethernet Device Server
PDS Series User Manual, Version 2.5, Mar. 2019
-
97 -
4.3.2
Set Remote VCOM3 Connection
Clicking the
“Set Remote VCOM3 Connection”
will display the
PDS Remote Vcom3 connection
Setup Page
allowing your enable and configure the pair connections for the PDS series, which will
be described in more detail below.
The following is an overview of the parameters contained in the
Remote Vcom3 connection Setup
Page
section:
Item
Description
Add COM “Number”
Serial COM port number of the local device (Master)
connect to COM “Number”
Serial COM port number of the remote device (Slave)
@ IP= “IP Address”
IP address of the remote device (Slave)
cmd port= “command port”
(default: 10000)
Command Port number of the remote device (Slave)
Add COM “Number”
Serial COM port number of the local device (Master)
connect to IP= “IP Address”
IP address of the remote device (Slave)
Port= “TCP port”
TCP Port number of the remote device (Slave)
MODBUS gateway
If the “MODBUS gateway” checked, the serial port is specified as
gateway from the Modbus RTU or Modbus ASCII (Master) to Modbus
TCP for the remote device (Slave)