Programmable Serial-to-Ethernet Device Server
PDS Series User Manual, Version 2.5, Mar. 2019
-
208 -
Appendix A: Linking to a Development PC
Step 1:
Connect the download-cable (CA0910), between the PDS and COM 1 of the development PC.
1-1: Connect the connector of CA-0910 download cable to your host computer.
1-2: Wire the CA-0910 to PDS, as follows:
Connect the CA-0910.TX with PDS.TxD
Connect the CA-0910.RX with PDS.RxD
Connect the CA-0910.GND with PDS.GND
Step 2:
Connect the
INIT* pin to the GND pin
.
Step 3:
Apply power (+Vs, GND) to the PDS series module.
Supply
24 V
DC
(+10 ~ +30 V
DC
) power
to the PDS(M)-700 Series.
Supply
24 V
DC
(+12 ~ +48 V
DC
) power
to the PPDS(M)-700-MTCP, DS-700, PPDS-700-IP67,
PDS-782-25 and PDS-5105D-MTCP Series.
Refer to below illustration for how to perform the above procedure.