Programmable Serial-to-Ethernet Device Server
PDS Series User Manual, Version 2.5, Mar. 2019
-
194 -
9.3.22
CONFIG
This command is used to clear the settings in the EEPROM.
Effect:
Immediate
Command
Arguments
Description
config
= RESET
Clears the settings in the EEPROM.
After reboot, the firmware will use the new (default) settings on
EEPROM.
Note: "RESET" MUST be in capital letters.
※
When “Config=RESET” is used, the Password, Alias and IPFILTER settings will also be cleared,
but the IP/MASK/GATEWAY addresses will not.
※
The SystemTimeout setting is also cleared to 0 by the "config=RESET" command, you have to
configure the SystemTimeout value again. The default factory setting of SystemTimeout value
should be 300000 ms (= 300 seconds).
Figure 9-3.22:
The following is an example of a
CONFIG
configuration.