Programmable Serial-to-Ethernet Device Server
PDS Series User Manual, Version 2.5, Mar. 2019
-
86 -
Item
Description
Default
Network WDT timeout
(System Timeout) (ms)
If the PDS series does not receive any data from any of the
clients within the period of the
“Network WDT timeout”
, the
module will reboot itself.
This setting is the same as
“SystemTimeout”
setting (unit: ms)
on Console/Telnet command, and is the same as
“/STxxx”
in
command line parameter (unit: seconds).
When user uses
“config=RESET”
Console/Telnet command to
clear the EEPROM, the
“Network WDT timeout”
(SystemTimeout, /ST) setting will also be cleared to 0.
Users have to configure this setting again by
“SystemTimeout” Console/Telnet command.
0 = Disabled
Min. setting value = 30000
0
(Disabled)
Master IP
If the Master IP is set, only the client using Master IP can
change the COM Port configuration. It is to prevent the COM
Port configuration changed by other clients.
empty
Reset System
If the “
Reset System
” option is checked, the PDS series will reboot itself after
the saving operation is complete, otherwise the original settings will still be
valid until the next power-on.
SET TCP/IP
Click this button to save the revised settings to the PDS series.