Programmable Serial-to-Ethernet Device Server
PDS Series User Manual, Version 2.5, Mar. 2019
-
116 -
8.
Check the
Local COM Port/Remote COM port
area for pair-connection setting.
9.
Reboot
PDS-700 #1(Client)
and then setting is complete.
Step 4: Configuring the PDS-782 (PDS-700 #2) in Server Mode
1.
Enter the URL address of the PDS-700 #2
in the address bar of the browser or click the
“Web”
button in the VxComm Utility to log in to the web configuration page.
2.
Click the
“
COM Port Settings
”
tag to enter the settings page, and select the appropriate
COM
Port number,
Baud Rate and Data Format
settings from the relevant drop down options
depending on the model and type of module being used as the Modbus slave device, for
example
“9600”
, “
8”, “None”
and
1
” .
3.
Check the “
Save current settings to EEPROM
” and “
Apply Current settings
” items, and then
click the
“
SET COM PORT
”
button to finish configuration.
4.
Click
“Set Remote VCOM3 connection”
at the PDS-700 #2 (Server) COM PORT setup page.
Refer to Figure 5-5.4 for illustrations of how to perform the Steps 2 to 4.