Programmable Serial-to-Ethernet Device Server
PDS Series User Manual, Version 2.5, Mar. 2019
-
94 -
4.3.1
Operation Mode: M0, M1, M2 and M3
M0: Transparent Mode (Multi-echo, shared)
M0 is used for Virtual COM and TCP/IP connections. In this mode, data is transmitted to each client
that is connected to the PDS series module.
Condition 1:
One client sends a request to the PDS series to access a device. The PDS series
transmits the data from device to each connected client.
Condition 2:
No clients send any requests to the PDS series. The PDS series transmits data from the
device to each connected client.