Programmable Serial-to-Ethernet Device Server
PDS Series User Manual, Version 2.5, Mar. 2019
-
95 -
M1: Slave Mode (Single-echo, Non-shared)
M1 is used for Virtual COM and TCP/IP connections. In this mode, data is transmitted to the specific
client that requested the service. If the client does not send a request to the COM port of the PDS
series module, then the module won't return any data to it.
Condition 1:
One client sends a request to the PDS series to access a device. The PDS series
transmits
data from the device to the client that requested the service.
Condition 2:
No clients send any requests to the PDS series. The PDS series doesn’t transmit any
data from the device to any client.