
Table 26. Environmental status and maintenance commands
Command
Information Displayed
sensorShow
v
Temperature readings for the port blades
v
Temperature readings for the CP blades
v
Status and RPM of all operational fans
v
Status of all operational power supplies
tempShow
v
Temperature readings for the port blades
v
Temperature readings for the CP blades
psShow
Status of all operational power supplies
fanShow
Status and RPM of all operational fans
chassisShow
Serial number, time awake, and additional information about
each component
slotShow
Slot occupancy
errShow
errDump
System error log. Refer to the
Fabric OS Message Reference
for
more information on the messages in this log.
Interpreting POST and boot results
The SAN768B performs power on self test (POST) by default each time the system
is powered on, rebooted, or reset. The system can be rebooted using the
reboot
(to
reboot each CP individually), or
fastBoot
commands. The
fastBoot
command
reboots the system without running POST. If the active CP blade is rebooted, it
fails over to the standby CP blade.
POST
The system automatically performs POST each time it is powered on or reset.
To verify that POST has completed without error:
v
Verify that all LEDs return to a normal state after POST completes (see
Chapter 4, “Monitoring system components,” on page 47).
If one or more LEDs do not return to a normal state, and this is not due to the
SAN768B being set to beacon, refer to the relevant LED table to identify and
correct the problem. For port blades, CP blades, and core switch blades, the
slotShow
command can be used to check the status of the slots. For information
about turning beaconing on/off, refer to the
Fabric OS Administrator's Guide
.
v
Verify that the switch prompt displays when POST completes.
If it does not display, POST was not successfully completed. Contact IBM for
support.
v
Review the system error log using the
errShow
or
errDump
commands.
v
Any errors detected during POST are written to the system log, which is
accessible through the
errShow
command. For information about error
messages, refer to the
Fabric OS Message Reference
.
POST includes the following steps:
1.
Preliminary POST diagnostics are run.
2.
Operating system is initialized.
3.
Hardware is initialized.
148
SAN768B Installation, Service, and User Guide
Содержание SAN768B
Страница 2: ......
Страница 8: ...vi SAN768B Installation Service and User Guide ...
Страница 12: ...x SAN768B Installation Service and User Guide ...
Страница 14: ...xii SAN768B Installation Service and User Guide ...
Страница 16: ...xiv SAN768B Installation Service and User Guide ...
Страница 28: ...xxvi SAN768B Installation Service and User Guide ...
Страница 32: ...xxx SAN768B Installation Service and User Guide ...
Страница 42: ...10 SAN768B Installation Service and User Guide ...
Страница 62: ...30 SAN768B Installation Service and User Guide ...
Страница 78: ...46 SAN768B Installation Service and User Guide ...
Страница 100: ...68 SAN768B Installation Service and User Guide ...
Страница 154: ...122 SAN768B Installation Service and User Guide ...
Страница 178: ...146 SAN768B Installation Service and User Guide ...
Страница 184: ...152 SAN768B Installation Service and User Guide ...
Страница 202: ...170 SAN768B Installation Service and User Guide ...
Страница 207: ......
Страница 208: ... Part Number 45W8666 Printed in USA GA32 0574 05 1P P N 45W8666 ...