v
Port blade
v
Phillips screwdriver
v
Small form factor pluggable (SFP) transceivers (as needed)
v
Optical cables (as needed)
Procedures
Follow the links in the steps below to complete this installation:
1.
Remove the chassis door. See “Removing and installing the chassis door” on
page 69.
2.
Verify that the port blade is the correct part: 21R9996 for the 16-port blade,
and 21R9997 for the 32-port blade, and 21R9998 for the 48-port blade.
3.
Verify which slot to install the blade. Slots are numbered from one through
ten, from left to right, when facing the port side of the SAN768Bs. Port blades
can be installed in any of the slots 1-4 and 9-12.
4.
We recommend having the latest firmware version on the CP blade. If the
firmware is not at the latest level, obtain new code from the code download
website, and install it prior to installing the port blade. See “Removing and
installing port, application, and encryption blades” on page 71.
Note:
Firmware downloads require that Ethernet connections be made to both
CP blades. Procedures for loading firmware are described in the
Fabric
OS Administrator's Guide
.
Attention:
A filler panel should be removed only when being replaced with
a port blade or new filler panel. Any slot that is not occupied by a port blade
should be occupied by a filler panel to ensure correct cooling of the chassis
and protection from dust.
5.
Remove the filler panel or port blade. Refer to “Removing a filler panel” on
page 75 or “Removing a blade” on page 72.
6.
Follow the instructions for “Installing a blade” on page 74.
7.
Follow the instructions for “Removing and installing transceivers” on page 96.
Because of port density, it may be easier to remove and install the SFPs while
the 32-port or 48-port blade is out of the chassis. However, you must handle
the blade carefully while it is out of the chassis to avoid damaging it.
8.
Install, group and route the cables as desired. See “Managing cables” on page
40 for additional cabling instructions.
Attention:
Do not route cables in front of the exhaust vent, which is located
at the top on the port side of the chassis.
9.
Verify the installation (see the appropriate section of Chapter 4, “Monitoring
system components,” on page 47). For information about how to check the
status of hardware components using the CLI, see the
Fabric OS
Administrator's Guide
, which is located on the product documentation CD.
10.
Reinstall the chassis door. See “Removing and installing the chassis door” on
page 69.
124
SAN768B Installation, Service, and User Guide
|
Содержание SAN768B
Страница 2: ......
Страница 8: ...vi SAN768B Installation Service and User Guide ...
Страница 12: ...x SAN768B Installation Service and User Guide ...
Страница 14: ...xii SAN768B Installation Service and User Guide ...
Страница 16: ...xiv SAN768B Installation Service and User Guide ...
Страница 28: ...xxvi SAN768B Installation Service and User Guide ...
Страница 32: ...xxx SAN768B Installation Service and User Guide ...
Страница 42: ...10 SAN768B Installation Service and User Guide ...
Страница 62: ...30 SAN768B Installation Service and User Guide ...
Страница 78: ...46 SAN768B Installation Service and User Guide ...
Страница 100: ...68 SAN768B Installation Service and User Guide ...
Страница 154: ...122 SAN768B Installation Service and User Guide ...
Страница 178: ...146 SAN768B Installation Service and User Guide ...
Страница 184: ...152 SAN768B Installation Service and User Guide ...
Страница 202: ...170 SAN768B Installation Service and User Guide ...
Страница 207: ......
Страница 208: ... Part Number 45W8666 Printed in USA GA32 0574 05 1P P N 45W8666 ...