Beginning troubleshooting and problem analysis
This information provides a starting point for analyzing problems.
This information is the starting point for diagnosing and repairing systems. From this point, you are guided
to the appropriate information to help you diagnose problems, determine the appropriate repair action,
and then complete the necessary steps to repair the system.
Note: Update the system firmware to the latest level before you start problem analysis. If you update the
system firmware, you will have the latest available fixes and improvements for error handling, reporting,
and isolation. For instructions about updating the system firmware, see Getting fixes.
What type of problem are you dealing with?
Problem analysis procedure
You do not know the type of problem.
Go to “Determining the problem analysis
procedure to perform” on page 1.
A baseboard management controller (BMC) access
problem occurred.
Go to “Resolving a BMC access problem” on page
The system does not power on (the power button
or the BMC power on command does not power on
the system).
Go to “Resolving a power problem” on page 5.
A system firmware boot failure occurred (the
system started but was not able to boot to the
Petitboot menu).
Go to “Resolving a system firmware boot failure”
A video graphics array (VGA) monitor problem
occurred (the system started but no video is
displayed on the monitor).
Go to “Resolving a VGA monitor problem” on page
An operating system boot failure occurred (the
system booted to the Petitboot menu but the
operating system did not start).
Go to “Resolving an operating system boot failure”
A sensor on the sensor readings GUI display is red. Go to “Resolving a sensor indicator problem” on
A processor, memory, power, or cooling hardware
failure occurred.
Go to “Resolving a hardware problem” on page
Missing or faulty PCIe adapter or device.
Go to Resolving a PCIe adapter or device problem.
You have an FQPSPxxxxxxx event code.
Go to FQPSPxxxxxxx Event Codes.
Determining the problem analysis procedure to perform
Learn how to identify the correct problem analysis procedure to perform.
About this task
To determine the correct problem analysis procedure to perform, complete the following steps:
Procedure
1. After you apply power to the system, are the power supply LEDs green (either steady or flashing)?
If
Then
Yes:
Continue with the next step.
©
Copyright IBM Corp. 2017, 2019
1
Содержание Power Systems Series
Страница 14: ...xiv Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...
Страница 88: ...74 Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...
Страница 101: ...Additional system parts Figure 14 Additional system parts Finding parts and locations 87...
Страница 115: ...Additional system parts Figure 23 Additional system parts Finding parts and locations 101...
Страница 122: ...108 Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...
Страница 133: ......
Страница 134: ...IBM...