Table 10. Sensor information, event description, and service action for the 5104-22C, 9006-12P,
9006-22C, or 9006-22P (continued)
Sensor name (Sensor ID)
Event description
Service action
• Freq Limit Pwr 1 (0x69)
• Freq Limit Pwr 2 (0x6D)
Performance Met
If Asserted is in the event
description, no service action is
required.
If Deasserted is in the event
description, ensure that both
power supplies are working
properly. Search for serviceable
events related to system power
and voltage and resolve them.
Ensure all fans are working
properly by looking for
serviceable events related to fans
and resolving them.
Performance Lags
If Deasserted is in the event
description, no service action is
required.
If Asserted is in the event
description, ensure that both
power supplies are working
properly. Search for serviceable
events related to system power
and voltage and resolve them.
Ensure all fans are working
properly by looking for
serviceable events related to fans
and resolving them.
Beginning troubleshooting and problem analysis 39
Содержание Power Systems Series
Страница 14: ...xiv Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...
Страница 88: ...74 Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...
Страница 101: ...Additional system parts Figure 14 Additional system parts Finding parts and locations 87...
Страница 115: ...Additional system parts Figure 23 Additional system parts Finding parts and locations 101...
Страница 122: ...108 Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...
Страница 133: ......
Страница 134: ...IBM...