Replace the PCIe adapter. Go to “5104-22C or 9006-22C locations” on page 63, “9006-12P locations”
on page 75, or “9006-22P locations” on page 91 and use the slot number information in the operating
system log to identify the physical location and the removal and replacement procedure.
Identifying the location of the NVMe Flash adapter
Use this procedure to identify the location of a Non-Volatile Memory Express (NVMe) Flash adapter.
Procedure
1. Does the operating system log contain the slot number? For example, the log might contain an error
message similar to the following text:
[131779.752714] EEH: PHB#0 failure detected, location: WIO-R Slot
If
Then
Yes:
Replace the adapter. Go to “5104-22C or 9006-22C locations” on page 63,
“9006-12P locations” on page 75, or “9006-22P locations” on page 91 and use the
slot number information to identify the physical location and the removal and
replacement procedure. This ends the procedure.
No:
Continue with the next step.
2. Locate the NVMe Flash adapter by using the PCI address:
a) The operating system log contains information about the NVMe Flash adapter in the form of a PCI
address. Record the PCI address information for the NVMe Flash adapter that has failed. For
example, in the operating system log message
nvme 0006:01:00.0: Failed status:
ffffffff, reset controller
, the PCI address of the failing NVMe Flash adapter is
0006:01:00.0.
b) At the command line, type
lscfg -vl pciaddress
, where
pciaddress
is the NVMe Flash
adapter information that you recorded in step 2.a. Then, press Enter.
c) Record the slot number information that is in the location code field.
d) Replace the adapter. Go to “5104-22C or 9006-22C locations” on page 63, “9006-12P locations”
on page 75, or “9006-22P locations” on page 91 and use the slot number information to identify
the physical location and the removal and replacement procedure. This ends the procedure.
Identifying the location of the storage device
Use this procedure to identify the location of a storage device.
About this task
The storage device location is determined in the drive removal and replacement procedures for your
system. See Removing a disk drive from the 5104-22C or 9006-22C system, Removing and replacing a
storage drive in the 9006-12P, or Removing and replacing a disk drive in the 9006-22P.
User guides for PCIe adapters
Use this information to find the user guide for your PCIe adapter.
About this task
Use the following table to find the user guide for the PCIe adapter that you are using.
Table 7. PCIe adapter user guides
Name
User guide
Broadcom
Broadcom website (http://www.broadcom.com)
Beginning troubleshooting and problem analysis 17
Содержание Power Systems Series
Страница 14: ...xiv Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...
Страница 88: ...74 Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...
Страница 101: ...Additional system parts Figure 14 Additional system parts Finding parts and locations 87...
Страница 115: ...Additional system parts Figure 23 Additional system parts Finding parts and locations 101...
Страница 122: ...108 Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...
Страница 133: ......
Страница 134: ...IBM...