Table 10. Sensor information, event description, and service action for the 5104-22C, 9006-12P,
9006-22C, or 9006-22P (continued)
Sensor name (Sensor ID)
Event description
Service action
• PS1 Status (0xF3)
• PS2 Status (0xF4)
• Predictive Failure
• Power Supply Input Out of
Range But Present
If the sensor name is PS1 Status,
replace PSU 1. If the sensor
name is PS2 Status, replace PSU
2. Go to “5104-22C or 9006-22C
75, or “9006-22P locations” on
page 91 to identify the physical
location and removal and
replacement procedure.
Power Supply Failure Detected
An assert event immediately
followed by a deassert event
indicates that a power cycle of
the system occurred. No service
action is required. If there is no
deassert event immediately
following the assert event,
replace the power supply. If the
sensor name is PS1 Status,
replace PSU 1. If the sensor
name is PS2 Status, replace PSU
2. Go to “5104-22C or 9006-22C
75, or “9006-22P locations” on
page 91 to identify the physical
location and removal and
replacement procedure.
• Power Supply Input Lost or AC
DC
• Power Supply Input Lost Or Out
Of Range
• Ensure that AC power is
supplied to the rack.
• Ensure that the system power
cords are plugged tightly into
both the power supply and the
rack power distribution unit
(PDU) for both system power
supplies.
• State Deasserted
• State Asserted
• Presence Detected
No service action is required.
48 Power Systems: Problem analysis, system parts, and locations for the 5104-22C, 9006-12P, 9006-22C, and
9006-22P
Содержание Power Systems Series
Страница 14: ...xiv Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...
Страница 88: ...74 Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...
Страница 101: ...Additional system parts Figure 14 Additional system parts Finding parts and locations 87...
Страница 115: ...Additional system parts Figure 23 Additional system parts Finding parts and locations 101...
Страница 122: ...108 Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...
Страница 133: ......
Страница 134: ...IBM...