Resolving an NVMe Flash adapter problem
Learn about the possible problems and service actions that you can perform to resolve a Non-Volatile
Memory Express (NVMe) Flash adapter problem.
About this task
Note: To determine the location of the NVMe Flash adapter, see “Identifying the location of the NVMe
Table 5. NVMe Flash adapter problems and service actions
Problem
Service action
System is unable
to find the NVMe
Flash adapter
1. If the system was recently installed, moved, serviced, or upgraded, verify that the
NVMe Flash adapter is seated and installed properly.
2. Verify that the NVMe Flash adapter is compatible with the system.
3. Verify that the most recent firmware is installed on the system. Otherwise install
the most recent firmware if it is not already installed.
4. Replace the NVMe Flash adapter.
NVMe Flash
adapter stops
working suddenly
1. Check the system logs to verify whether the system detected a problem.
2. Replace the NVMe Flash adapter.
Other problems
Check the messages and resolve any other problems that are detected. Then, test
the NVMe Flash adapter again.
Resolving a storage device problem
Learn about the possible problems and service actions that you can perform to resolve a storage device
problem.
About this task
Note: To determine the location of the storage device, see “Identifying the location of the storage device”
Table 6. Storage device problems and service actions
Problem
Service action
System is unable to find more than one storage
device
1. If the system was recently installed, moved,
serviced, or upgraded, verify that the device is
seated and installed properly.
2. Verify that the device is compatible with your
system.
3. Verify that all internal cables are properly
seated and are not physically damaged.
4. Verify that the most recent firmware is installed
on the system, or install the most recent
firmware if it is not already installed.
5. If the devices are part of a RAID configuration,
ensure that the device has been enabled and is
part of an array.
6. Replace the cable that connects the disk drive
backplane to the system backplane.
Beginning troubleshooting and problem analysis 15
Содержание Power Systems Series
Страница 14: ...xiv Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...
Страница 88: ...74 Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...
Страница 101: ...Additional system parts Figure 14 Additional system parts Finding parts and locations 87...
Страница 115: ...Additional system parts Figure 23 Additional system parts Finding parts and locations 101...
Страница 122: ...108 Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...
Страница 133: ......
Страница 134: ...IBM...