a. Ensure that a problem does not exist with the connection to the network location.
b. Ensure that the adapter has a valid IP address for the network.
c. Replace the network adapter.
• If your system is a 5104-22C or 9006-22C, go to “5104-22C or 9006-22C locations” on page
63 to identify the physical location and the removal and replacement procedure.
• If your system is a 9006-12P, go to “9006-12P locations” on page 75 to identify the physical
location and the removal and replacement procedure.
• If your system is a 9006-22P, go to “9006-22P locations” on page 91 to identify the physical
location and the removal and replacement procedure.
4. Petitboot displays all recognized bootable images to use by default. Is the boot image recognized by
Petitboot?
If
Then
Yes:
Continue with step “10” on page 9.
No:
Select the Petitboot menu option to refresh the boot images. If the problem persists,
continue with the next step.
5. To determine the command to type on the Petitboot command line to verify that the boot drive is
recognized and in optimal status, use Table 1 on page 8.
Table 1. Determine the command to verify that the boot drive is recognized and in optimal status
Boot drive configuration
Commands
Virtual drive connected directly to the system
backplane
arcconf getconfig 1 LD
Physical drive connected directly to the system
backplane
arcconf getconfig 1 PD
Is the boot drive recognized and in optimal status?
If
Then
Yes:
Reinstall the operating system on the boot drive. This ends the procedure.
No:
Continue with the next step.
6. Are the drives properly seated in their respective drive bays?
Note:
• If your system is a 5104-22C or 9006-22C, go to “5104-22C or 9006-22C locations” on page 63
to identify the physical location and the removal and replacement procedure.
• If your system is a 9006-12P, go to “9006-12P locations” on page 75 to identify the physical
location and the removal and replacement procedure.
• If your system is a 9006-22P, go to “9006-22P locations” on page 91 to identify the physical
location and the removal and replacement procedure.
If
Then
Yes:
Continue with the next step.
No:
Properly seat the drives in the drive bays. Then, go to step “4” on page 8.
7. Refresh the Petitboot boot options. Is the boot image on the boot drive recognized?
If
Then
Yes:
Boot the operating system. Then, continue with step “10” on page 9.
No:
Continue with the next step.
8 Power Systems: Problem analysis, system parts, and locations for the 5104-22C, 9006-12P, 9006-22C, and
9006-22P
Содержание Power Systems Series
Страница 14: ...xiv Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...
Страница 88: ...74 Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...
Страница 101: ...Additional system parts Figure 14 Additional system parts Finding parts and locations 87...
Страница 115: ...Additional system parts Figure 23 Additional system parts Finding parts and locations 101...
Страница 122: ...108 Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...
Страница 133: ......
Страница 134: ...IBM...