• If your system is a 9006-12P, go to “9006-12P locations” on page 75 to identify the physical
location and the removal and replacement procedure.
• If your system is a 9006-22P, go to “9006-22P locations” on page 91 to identify the physical
location and the removal and replacement procedure.
• If the sensor name is CPU Func 1 or CPU Core Func x, where x is 1 - 12, replace system processor
CPU 1.
• If the sensor name is CPU Func 2 or CPU Core Func x, where x is 13 - 24, replace system processor
CPU 2.
Does the problem persist?
If
Then
Yes:
Replace the system backplane. If the replacement of the system backplane does not
resolve the problem, go to “Contacting IBM service and support” on page 61. This
ends the procedure.
No:
This ends the procedure.
EPUB_PRC_SP_CODE isolation procedure
A problem was detected in the system firmware.
About this task
Update the system firmware image. Go to Getting fixes and update the system firmware with the most
recent level of firmware. Then, reboot the system. If the system firmware update does not resolve the
problem, go to “Contacting IBM service and support” on page 61. This ends the procedure.
EPUB_PRC_PHYP_CODE isolation procedure
A problem was detected in the system firmware.
About this task
Update the system firmware image. Go to Getting fixes and update the system firmware with the most
recent level of firmware. Then, reboot the system. If the system firmware update does not resolve the
problem, go to “Contacting IBM service and support” on page 61. This ends the procedure.
EPUB_PRC_ALL_PROCS isolation procedure
A problem was detected with a system processor.
About this task
Use the following table to determine the service action:
50 Power Systems: Problem analysis, system parts, and locations for the 5104-22C, 9006-12P, 9006-22C, and
9006-22P
Содержание Power Systems Series
Страница 14: ...xiv Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...
Страница 88: ...74 Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...
Страница 101: ...Additional system parts Figure 14 Additional system parts Finding parts and locations 87...
Страница 115: ...Additional system parts Figure 23 Additional system parts Finding parts and locations 101...
Страница 122: ...108 Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...
Страница 133: ......
Страница 134: ...IBM...