Table 10. Sensor information, event description, and service action for the 5104-22C, 9006-12P,
9006-22C, or 9006-22P (continued)
Sensor name (Sensor ID)
Event description
Service action
• CPU Func 1 (0x0C)
• CPU Func 2 (0x0E)
• IERR
• Transition to Non-recoverable
• Predictive Failure
If the sensor name is CPU Func 1,
replace CPU 1. If the sensor
name is CPU Func 2, replace CPU
2. Go to “5104-22C or 9006-22C
75, or “9006-22P locations” on
page 91 to identify the physical
location and removal and
replacement procedure.
• Thermal Trip
• FRB1 BIST Failure
• FRB2 Hang In POST Failure
• FRB3 Processor Startup
Initialization Failure
• Configuration Error
• SMBIOS Uncorrectable CPU
Complex Error
• Processor Disabled
• Terminator Presence Detected
• Processor Automatically
Throttled
• Machine Check Exception
• Correctable Machine Check
Error
• State Deasserted
• Device Disabled
• Transition to Critical from Less
Severe
• Transition to Non-recoverable
from Less Severe
• Transition to Critical from Non-
recoverable
• Processor Presence Detected
• State Asserted
• Device Enabled
• Transition to OK
• Transition to Non-Critical from
OK
• Transition to Non-Critical from
More Severe
• Monitor
• Informational
No service action is required.
Beginning troubleshooting and problem analysis 29
Содержание Power Systems Series
Страница 14: ...xiv Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...
Страница 88: ...74 Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...
Страница 101: ...Additional system parts Figure 14 Additional system parts Finding parts and locations 87...
Страница 115: ...Additional system parts Figure 23 Additional system parts Finding parts and locations 101...
Страница 122: ...108 Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...
Страница 133: ......
Страница 134: ...IBM...