Chapter 7. Error Recovery Procedures
The Internal Disk provides 24-byte compatibility sense data and 32-byte sense
data. The 24-byte compatibility sense indicates the error recovery and logging
actions in bytes 0–2. The 32-byte sense indicates these actions in bytes 24 and
25.
“ERPs for 24-Byte Compatibility Sense” defines ERP requirements when the sense
data is 24-byte compatibility sense (sense byte 27, bit 0 is ‘1’). “ERPs for ECKD
32-Byte Sense” on page 7-5 defines ERP requirements when the sense data is
ECKD 32-byte sense (sense byte 27, bit 0 is ‘0’).
ERPs for 24-Byte Compatibility Sense
Table 7-1 identifies all unique bit configurations in bytes 0 through 2, and maps
each of these configurations to a specific recovery action for the host program.
“Error Recovery Actions” on page 7-2 describes the error recovery action (
Act
) in
Table 7-1.
If logging (shown as
Log
in Table 7-1) is specified, the host program must create
an Outboard Recorder (OBR) type 30 record.
With the exception of message to operator, and imprecise ending, the bit
combinations in Table 7-1 represent all valid combinations. Message to operator,
and imprecise ending can be active with several combinations.
Table
7-1 (Page 1 of 2). Error Conditions
Byte
Bit
Sense Data
Condition
Act
Log
0
0
Command Reject
Programming error.
2
No
0
2
0
3
Command Reject
Environmental Data
Present
Trying to perform a special command on an interface
disabled by the Perform Subsystem Function
command with the Set Special Intercept Condition
order.
10
No
0
1
Intervention Required
Logical volume off-line or not installed.
3
No
0
3
Equipment Check
Subsystem equipment check or processing error.
5
Yes (1)
0
1
3
0
Equipment Check
Permanent Error
Equipment fault - retry exhausted or undesirable.
1
Yes
0
1
2
3
0
3
Equipment Check
Permanent Error
Environmental-Data
Present
Equipment fault; retry exhausted or undesirable. The
causes include a subsystem processing error.
4
Yes (1)
0
2
3
3
Equipment Check
Environmental-Data
Present
Internal error recovery actions recovered from an
equipment check or reset notification log.
4
Yes (1)
0
1
4
0
Data Check
Permanent Error
Unrecoverable Data Check
1
Yes
1
1
Invalid Track Format
Track capacity exceeded.
2
No
(1) The sense data is not logged if the Format (byte 7, bits 0–3) is ‘0’ or ‘F’.
Copyright IBM Corp. 1999
7-1
Содержание Multiprise 3000
Страница 1: ...S 390 Multiprise 3000 Enterprise Server R IBM Internal Disk Subsystem Reference Guide SA22 1025 00 ...
Страница 2: ......
Страница 3: ...S 390 IBM Internal Disk Subsystem Reference Guide SA22 1025 00 ...
Страница 32: ...2 12 Internal Disk Subsystem Reference Guide ...
Страница 38: ...3 6 Internal Disk Subsystem Reference Guide ...
Страница 182: ...4 144 Internal Disk Subsystem Reference Guide ...
Страница 198: ...5 16 Internal Disk Subsystem Reference Guide ...
Страница 214: ...6 16 Internal Disk Subsystem Reference Guide ...
Страница 234: ...A 10 Internal Disk Subsystem Reference Guide ...
Страница 238: ...B 4 Internal Disk Subsystem Reference Guide ...
Страница 243: ...4 lease the Code or any copy of it Appendix C Warranties C 5 ...